COMMANDES
SIGNAL
SAFETY
ETME Product
Conformity EC
Conform to the norm
NFC 15-100
PRODUCT
PIC 201A S
Tighten the unused cable glands to maintain the given IP
Power supply voltage : 400Vac ±10% + Earth.
Rated insulation voltage : 400 VAC
Neutral System : TN / TT / IT.
Maximum power consumption : 100mA / 400Vac (Not including 400 VAC external loads)
Operating Temperatures: -10°C - +50°C.
1 pluggable terminal block / 2,5mm² maximum cross section.
1 transformer 36VA mounted on circuit board.
2 inputs "Door position and Wheel Lock".
1 "operating" led ( lit when the board is functioning ).
1 command " up " on Deadman operating only.
1 output " hydraulic unit " 2.2Kw / 400Vac.
1 output " valve DC "25W" configurable into 12V or 24V.
1 output " Valve AC - 25W configurable into 12V or 24V.
CONFORMITY
EQUIPMENT
- ISOLATOR SWITCH
- DIFFERENTIAL CIRCUIT
BREAKER
*
- ....
MOTOR
*
PROTECTIONS
MOTORS
TECHNICAL CARACTERISTICS
Type of IP 54 Enclosure
External Dimensions
Vertical leak proof plastic 220 x 172 x 150
INSTALLATION
-
CABLE
SECTION
- METER
- ISOLATION
-
- ....
THE ENVIRONMENT OF ETME'S PRODUCT MUST
BE BROUGHT INTO CONFORMITY WITH ALL EU
DIRECTIVES THAT APPLY AND THE APPLICABLE
SECTIONS OF THE INSTALLATION STANDARDS
IN FORCE ON THE GEOGRAPHICAL AREA OF
COMMISSIONING, THIS BEING THE RESPONSIBILITY
OF INSTALLER, PRIMARILY FOR THE CONDITIONS
CONNECTING , ISOLATION AND PROTECTION
OF PERSONS AND PROPERTY
* MOTOR PROTECTION MUST BE SECURED BY A
MAGNETOTHERMIC BREAKER SCHNEIDER
TYPE GV2ME (RESPECT FOR TYPE 1 COORDINATION)
FOLLOWING PRODUCTS, INTERNAL OR EXTERNAL
PROTECTIONS IN ETME BOX
PIC 201 AS ELECTRONIC BOARD
MUST BE PLACED IN AN
IP54 MINIMUM ENCLOSURE.
Mechanical Fastener Sliding Gland
X in mm Y in mm
186
POWER LINE
DIFFERENTIAL MAIN
CIRCUIT BREAKE
R
N° 20
106
2
NOTPIC201AS-T-01 3/8
Normal
Gland
N° 16
4