Note: This appliance is also provided with a window slider kit. You can use it to fix the hot air exhaust hose
to the window. The installation of the window slider kit is mostly in "horizontal" way or in "vertical" way.
Check the minimum and maximum size of your window before installation. (Fig.5 & Fig.6)
-
Attach the window slider kit onto the window.
-
Adjust the length of the window slider kit according to the window width or height. Fix it with the
dowel. (Fig.7)
-
Insert the hot air exhaust hose to the hole of the window slider kit. (Fig.8)
Fig.5
Fig.7
Fig.8
OPERATION
Always let the appliance rest for at least 2 hours after moving it from one location to another.
Before use, check up whether the exhaust hose has been mounted properly. Plug in the appliance.
1. Power button
Press the button "POWER" to turn on the appliance. The appliance will begin to work under cooling mode
at low wind speed. Press the button again, the appliance will be turned off.
2. Temperature (timer) increasing button & temperature (timer) decreasing button
Press the button "TEMP+"/"TEMP-" to set your desired room temperature from 16℃ to 31℃. The
buttons can also be used for timer adjustment from 1-24 hours during timer setting. The value will be
increased/decreased by 1 (℃/hour) for each press. Long press for rapid adjustment.
Please note: The appliance will turn off the compressor (for cooling) automatically once the room
- 27 -
Fig.6