Setting up and site of deployment

Warning
The radiant gas heater is intended above all for use in an outdoor. Make certain that adequate fresh air circulation is always
ensured.
Always remain at a safe distance from flammable material – at least 45 cm (18") from the top and
at least 70 cm (28") from the sides.
The radiant gas heater must stand on firm and level ground.
Never operate the radiant gas heater in a potentially explosive atmosphere, such as in areas where petrol or other flammable
liquids or vapours are stored.

Leakage testing

Warning
The gas connections of this radiant gas heater have been tested for leakage at the factory before delivery. However, complete
testing for leakage of gas must be carried out at the assembly site due to the possibility of improper transport or due to excessive
pressure on the radiant gas heater.
Test the radiant gas heater with a full gas bottle.
Make certain that the safety valve is turned to the OFF position.
Prepare a soap solution from one part liquid detergent and one part water. Apply the soap solution with a spray bottle, brush
or cloth.
In the event of leakage soap bubbles will form.
Turn the gas inlet to ON.
If you detect a leak, turn off the gas supply. Tighten all leaking connections and then open the gas supply again.
Repeat the leakage testing. If soap bubbles still occur, contact your specialist supplier.
Never carry out leakage testing while smoking or with an open flame.