Technical Specifications; Electrical Specifications - Sunrise Medical Oxford Arise Manuel De L'utilisateur Et Garantie

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

18

TECHNICAL SPECIFICATIONS

Safe Working Load ..........................................375 lbs
Maximum Overall Length...................................53.9 inches
Minimum Overall Length ...................................51.1 inches
Maximum Overall Height ...................................67.7 inches
Minimum Overall Height ...................................44 inches
Maximum Height to attachment point.................66.9 inches
Minimum Height to attachment point .................40.1 inches
Turning Radius ................................................55.9 inches
Legs Open - External Width ..............................40.5 inches
Legs Open - Internal Width ...............................35 inches
Legs Closed - External Width ............................24.8 inches
Legs Closed - Internal Width ............................20 inches
Overall Height of Legs ......................................4.7 inches
Ground Clearance.............................................1.4 inches
Front Twin Castors ...........................................4 inches
Rear Braked Castors .........................................4 inches
Weights
Mast, Base & Boom Assembly ............................108.9 lbs
Power Pack .....................................................6.6 lbs
Total..............................................................115.5 lbs
Base Assembly (not inc battery) ........................42.9 lbs
Mast & Boom (not inc battery) ..........................51.7 lbs
All measurements are within a +5/--5 degree of tolerance.
294000.10008 Rev. C
E n g l i s h
170 kgs
1370 mm
1300 mm
1720 mm
1120 mm
1700 mm
1020 mm
1420 mm
1030 mm
890 mm
630 mm
510 mm
120 mm
35 mm
100 mm
100 mm
49.5 kgs
3.00 kgs
52.5 kgs
19.5 kgs
23.5 kgs
E n g l i s h

ELECTRICAL SPECIFICATIONS

BATTERIES ......................................................12 volt Rechargeable sealed lead acid type
BATTERY CAPACITY ...........................................3.2 Ampere hours
CHARGER RATED INPUT .....................................230Vac 50/60Hz
CHARGER RATED OUTPUT...................................27.4/29.0 VDC@0.8A
Electric Shock Protection
CHARGER ........................................................CLASS II
LIFT...............................................................INTERNAL POWER SOURCE
Degree of Shock Protection
CHARGER ........................................................TYPE B
LIFT...............................................................TYPE B
INTENDED OPERATING ENVIRONMENT: .................>+5˚ <+40˚.