14
every 10-14 days
illustration 4: Switch off appliance and pull out switching power supply. Pour out soiled water.
Brush off precipitated deposits in the lower housing and flush out. Flush disk stack with water. Fill
lower housing with water again. Refill with Venta hygiene agent. For dosing, see scale on back of
bottle.
All residues in the lower housing and on the disk stack (white, green-yellowish or brownish precipi-
tation) do NOT impair the function of the Venta air washer. As a result of the addition of the hygiene
agent, trouble-free hygienic operation is guaranteed.
Dosage for models
LW 15 = Dosage for LW 14, LW 25 = Dosage for LW 24, LW 45 = Dosage for LW 44
See back of the bottle.

every six months

We recommend a six-monthly general cleaning with the Venta appliance cleaner. According to the
degree of pollution of the air washer, odors can possibly arise during cleaning. Please provide for
fresh air ventilation in these cases. The Venta appliance cleaner was especially designed to be com-
patible with Venta plastics, without attacking them. Please consider directions for use on bottle.

generaL cLeaning

illustration 5: Switch off the appliance and pull out switching power supply. For the opening of
the upper housing, press on the locking latch (see arrows).
illustration 6: It is absolutely necessary to consider the sequence during the opening of
the top cover: First pivot aside the two sides
3
4
wings
+
(with light pressure).
illustration 7: Remove mains cable connector from drive unit
mains cable from holder
• Do not dismantle unit and switching power supply, do not immerse in water and do not bring
into contact with liquid!
• Clean drive unit, fan blade and gearing with dry cloth!
• Dismantled upper housing can be cleaned under flowing water.
• Dismantled upper housing must be completely dry before assembly!!!
illustration 8: Place drive unit into the upper housing in correct alignment
connector up from underneath through the opening of the upper housing
unit until latched
illustration 9: Place the external ends of the latches in the up position (see rings)!
It is now absolutely necessary to follow the sequence: First pivot up the two ribbed wings
and after that the two side parts
illustration 10: Close the upper housing through pressing on the external ends of the latches
(see arrows).
3
and pull out through opening in the upper housing
3
. Clip mains cable into holder
3
+
4
1
+
2
and after that pivot out the two ribbed
1
4
.
and engage in latch.
. Lift out drive unit
2
. Remove
4
.
1
. Pull mains cable
2
and plug into drive
1
+
2

Publicité