Shut off power at the circuit breaker or fuse panel before removing the old fixture or installing a new one.
Read entire installation procedure before you begin and save instruction for future reference.
THIS FIXTURE IS DIMMABLE BY SPECIFIC FORWARD PHASE ELECTRONIC (TRIAC) DIMMERS. Dimmers tested to be compatible with this fixture are the Lutron
Skylark
SCL-153P*, Diva
DVCL-153P*, Maestro
®
®
dimmers does not imply any guarantee or warranty of compatibility with a particular application. Dimmers not listed do not imply non-compatibility.)
If unsure if the electrical box is properly grounded, or the box is plastic and has no ground wire, or are unfamiliar with the methods of properly grounding fixture,
consult a qualified electrician.
Important Safety
1. Do not look directly at LEDs for extended period of time.
2. Suitable for damp locations.
3. Turn power off before servicing.
4. Do not leave bare wires exposed.
5. For electrical requirements, see fixture. Minimum 90 °C supply conductors.
Care and Maintenance
Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner and soft cloth. When cleaning the fixture, make sure the power is turned off. Do not
spray cleaner directly onto any part of the fixture or LEDs.
x2
x2
Screw the two long machine screws through the threaded holes from the backside of the mounting bracket. On the front side of the mounting bracket, secure the hex nuts onto the screws
until they are flush with the mounting bracket.
Hold the mounting bracket up to the electrical box and pull the wires through the center opening of the mounting bracket. Use the short machine screws to attach the mounting bracket
flush to the electrical box. NOTE: If necessary, the elongated slots in the mounting bracket may be utilized to achieve the correct orientation for the installation.
Fixture must be properly grounded. Connect fixture ground wire to ground wire in electrical box using a wire nut. The ground wires can be either green or bare copper. If the electrical box
is metal and grounded, attach the green/copper ground wire from the fixture to the mounting plate using the grounding screw. Then connect black supply lead to black fixture wire and
white supply lead to white fixture wire using wire nuts. Secure the wire nuts properly to prevent the wires from coming loose. Push excess wire back into the electrical box.
x2
Before mounting fixture, make sure the closed catches on the endcaps are on the bottom to prevent the diffuser from falling out of the end caps. Secure the fixture to the electrical box
with the screw caps (FF). The back plate should be tight against the wall surface.
Once level hold the fixture in place and mark the locations of the mounting holes at both ends of the fixture. Drill a 3/16 in. pilot hole or use an awl or nail to dimple the marked locations.
Screw the drywall anchors into the marked locations until they are flush with the surface of the drywall. While holding the fixture in line with the previously installed drywall anchors,
screw both wood screws into the drywall anchors. NOTE: Make sure the fixture is level before fully tightening the wood screws.
Simultaneously, slide both ends of the diffuser evenly into the channels of each end caps. NOTE: If the diffuser will not line up with the channels, it may be neccessary to adjust the end
caps by carefully bending them in or out as needed. Once both ends of the diffuser are set in the openings of the end caps carefully push/pull the diffuser into place until it is securely
seated in the closed catches.
In order to hold the glass in place, insert the silicone pads between the diffuser and the end cap channel at each end. Restore power to the fixture.
Color changing toggle switch
interrupteur à bascule de
changement de couleur
interruptor de palanca de
cambio de color
Diffuser
Diffuseur
Difusor
WARNINGS AND CAUTIONS
MACL-153M*, Toggler
®
x2
x2
x2
Rampe d'éclairage à DEL Seattle pour meuble-lavabo (Page 3)
Required
Nécessaire
Obligatorio
End Caps
Capuchon
* Actual hardware may differ from illustration
Tapa de extremo
* La quincaillerie incluse peut être différente de l'illustration.
* Los aditamentos reales pueden diferir de los que se muestran en la ilustración.
TGCL-153P*, Lumea
LECL-153P*, Caseta
®
®
x3
Seattle LED Linear Vanity (Page 2)
Tocador lineal LED Seattle (Página 4)
Model / Model / Modelo #: VA1197-CHR-32LF3-G
1/8 in.
PD-6WCL*, Eaton Halo
SAL06P*. (This list of
®
®
x2

Publicité

loading

Sommaire des Matières pour Good Earth Lighting VA1197-CHR-32LF3-G

  • Page 1 Seattle LED Linear Vanity (Page 2) Rampe d’éclairage à DEL Seattle pour meuble-lavabo (Page 3) Tocador lineal LED Seattle (Página 4) Model / Model / Modelo #: VA1197-CHR-32LF3-G Required 1/8 in. Nécessaire Obligatorio Color changing toggle switch interrupteur à bascule de...
  • Page 2 Please visit our website at: www.goodearthlighting.com/support or call the Customer Care Center 1-800-291-8838, 8:30 a.m.-5 p.m., CST, Monday-Friday. Printed in China is a registered trademark of Good Earth Lighting, Inc. All rights Reserved. Good Earth Lighting ® Distributed by: Good Earth Lighting 1400 East Business Center Drive, Ste.
  • Page 3 1-800-291-8838 de 8h30 à 17h00, HNC, du lundi au vendredi. Imprimé en Chine Good Earth Lighting sont des marques de commerce déposéea de Good Earth Lighting, Inc. ® Distribué par : Good Earth Lighting 1400 East Business Center Drive, Ste. 108 Mount Prospect, IL 60056 ®...
  • Page 4 Sírvase visitar nuestro sitio web en: www.goodearthlighting.com/support o llame al Centro de Asistencia al Cliente al 1-800-291-8838, 8:30 a.m.-5 p.m., Hora Central Estándar (CST), de lunes a viernes Impreso en China son marcas registradas de Good Earth Lighting, Inc. Todos los derechos reservados. Good Earth Lighting ®...