General Description; Prior To Installation - American Standard Ultima 6047 Serie Instructions D'installation

Masquer les pouces Voir aussi pour Ultima 6047 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Roughing-in Dimensions
Fig.1
SUPPLY
DN 25 mm
108-133 mm
(1" I.P.S.)
(4-1/4" to 5-1/4")
-C-L-
*CRITICAL
LEVEL
152 mm
(6 " )
(Min.)
*Note: The Critical Line (-C-L-) on Vacuum Breaker
"
must typically be 6
Consult Codes for details.
See (Section 8) for converting
Flush Valve to Left Hand Installation.
RECOMMENDED TOOLS; Fig. 2
1. Teflon Tape
2. Flat Blade Screwdriver (For adjusting Supply Stop)
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench

PRIOR TO INSTALLATION

Note: Prior to installing the Selectronic
the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All
piping behind the walls should be properly secured
and fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
38mm-127mm
6047.122
ROUGH-IN
DIMENSION
686 mm
(27")
6047.121
ROUGH-IN
DIMENSION
292 mm
(11-1/2")
6047.117
ROUGH-IN
DIMENSION
610 mm
(24")
FOR 1-1/2" TOP
SPUD FIXTURES
(152mm) minimum above fixture.
Flush Valve
®
FINISHED WALL
(1-1/2-5")
6047.117
660 mm
(26")
6047.122
735 mm
(29")
6047.121
135 mm
(13-1/2")
Right or Left Hand Installation
Fig.2
1
5
7
• Flush all water lines prior to operation
(See Step 5). Dirt and debris can cause flush
valve to run continuously.
• With the exception of Supply Stop Inlet,
DO NOT use pipe sealant or plumbing grease
on any valve component or coupling!
• Protect the chrome or special finish on the
Flushometer. DO NOT USE toothed tools on
finished surfaces to install or service these
valves. Also see "Care and Cleaning" section
of this manual.
• This product contains mechanical and/or
electrical components that are subject to
normal wear. These components should be
checked on a regular basis and replaced as
needed to maintain the valve's performance.
3

GENERAL DESCRIPTION

MANUAL FLUSH VALVE
Exposed Flushometer
for 1-1/2" Top Spud Fixtures
OPERATING PRESSURE:
• Overall Range: 20-125 psi **
• Recommended: 25 psi (flowing)
80 psi (static)
FLOW REQUIREMENT:
• 25gpm (94.6 L/min).
** Water pressure over 80 psi is not
recommended with most plumbing fixtures
2
4
10'
6
9
M965022 Rev. 2.2 (5/19)
3
8
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ultima 7017 serie

Table des Matières