Wiring the device
Control terminals
Analog inputs, analog outputs
Terminal X3
SSP94000X3
Terminal data
Flexible
With wire end
ferrule
)
Note!
If the control terminals are completely wired, we recommend to use a cable
cross−section of max. 0.75 mm
be attached.

Digital outputs

Terminal X4
9400SSP000X4
Terminal data
Flexible
With wire end
ferrule
126
Labelling
Description
GA
GND analog signals
AO1
Analog output 1
AO2
Analog output 2
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
A2+
Analog input 2 +
A2−
Analog input 2 −
"
Shield connection: Fix the shield with EMC wire clamp.
Conductor cross−section
2
[mm
]
0.2 ... 2.5
2
Labelling
Description
GO
GND digital out
24O
24−V digital out
DO1
Digital output 1
DO2
Digital output 2
DO3
Digital output 3
DO4
Digital output 4
Conductor cross−section
2
[mm
]
0.2 ... 2.5
l
Tightening torque
[AWG]
[Nm]
24 ... 12
to save space. The mechanical cover can then
Tightening torque
[AWG]
[Nm]
24 ... 12
[lb−in]
Spring terminal
[lb−in]
Spring terminal