Material Included; Technical Data Roairvac R32 2.0 & 5.0 Cl; Technical Data Charger And Battery (D); Function Of The Unit - Rothenberger ROAIRVAC R32 2.0 CL Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
Dispatch batteries only when the housing is undamaged. Tape or mask off open contacts and
pack up the battery in such a manner that it cannot move around in the packaging. Please also
observe possibly more detailed national regulations.
2

Material included

1 x Vacuum pump
1 x Mineral oil bottle
1 x Connector 1/4" SAE F - 5/16" SAE M Adapter
1 x Connector 1/4" SAE F - 3/8" SAE M Adapter
1 x Instructions for use
3
Technical Data ROAIRVAC R32 2.0 & 5.0 CL
Battery voltage ...................................................
Flow rate ............................................................
Final vacuum .....................................................
Power ................................................................
Motor speed.......................................................
Refrigerant classes ............................................
Inlet ................................................................ ¼" SAE............................ ¼" SAE
Oil capacity ........................................................
Dimensions (L x W x H) without battery .............
Weight (without battery) ................................ c a. 3,7 kg, 8.15 lbs .......... ca. 7,5 kg, 16.5 lbs
Sound pressure level dB (A) L
Sound power level dB (A) L
The noise level during operation can exceed 85 dB (A). Wear ear protection!
Measured values determined in accordance with EN 60335-1.
4
Technical Data charger and battery
Battery:
U = Voltage
C = Capacity
W = Weight
Ic = Charge current
t
= Approx. charging time (90% full)
Charging voltage.............................
Charging temperature .. 0° - 50° C, 32° - 122° F
Max. discharging
temperature. ................................
Recharge battery pack before first use!
5

Function of the Unit

5.1
Description
Vacuum pump for air evacuation of closed systems (air conditioners, tanks, etc). This equipment
is specially designed for HVAC&R systems.
The two Stages of these pumps make it feasible to achieve the final vacuum level requested for
these type of systems. Besides, the solenoid non-return valve avoids any oil mixture due to the
backflow after a power interruption or any other process interruption.
ROAIRVAC R32 2.0 CL ROAIRVAC R32 5.0 CL
18 V ................................ 18 V
2.0 cfm/ 57 l/min .............. 5,0 cfm/ 142 l/min
23 micron ........................ 15 micron
185 W, 1/4 HP ................. 550 W, 3/4 HP
3600 RPM ....................... 1800 RPM
A1, A2L, A2 ..................... A1, A2L, A2
180 ml, 6 oz..................... 350 ml, 11 oz.
278×112×224 mm ...........
10.9"x4.4"x8.8"
¦ K
.................
≤ 62,2 ¦ 3 ........................ ≤ 65,4 ¦ 3
pA
pA
¦ K
...................
≤ 73,2 ¦ 3 ........................ ≤ 76,4 ¦ 3
WA
WA
20,75 V DC
5° - 50° C, 41° - 122° F
ENGLISH
321×150×266 mm
12.6"x5.9"x10.4"
Charger:
U1
= Input voltage
f1
= Input frequency
P1
= Input power
U2
= Charging voltage
= Max. charge current
I2
Nc
= No. of battery cells
W
= Weight
Pay attention to the electrical outlet
voltage! Check the label on the
bottom of the charger!
(D)
(A-B)
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Roairvac r32 5.0 cl10000032301000003233

Table des Matières