Setup function
Shaded areas below apply only to
9
Stage 1 compressor
cycle rate (CPH)
10 Stage 2 compressor
cycle rate (CPH)
12 Manual/Auto
changeover
13 Adaptive Intelligent
Recovery™
14 Temperature
display
15 Compressor
protection
16 Schedule format
26 Auxiliary heat
control
27 Heat temperature
range stops
28 Cool temperature
range stops

Special function

Auto Changeover (Setup Function 12): When set to Auto, the thermostat
automatically selects heating or cooling depending on the indoor temperature.
The thermostat will automatically adjust heat and cool settings to maintain
a 3-degree separation (fixed). Note: If you select Auto Changeover Only,
the System Setting on the thermostat will stay locked in the Auto position,
preventing the user from changing it to Em Heat, Heat, Cool or Off.
Adaptive Intelligent Recovery™ (Setup Function 13): Allows the thermostat
to "learn" how long the furnace and air conditioner take to reach programmed
temperature settings, so the temperature is reached at the scheduled time.
Compressor Protection (Setup Function 15): Forces the compressor to wait
a few minutes before restarting, to prevent damage. During the wait time, the
message Cool On or Heat On (heat pumps only) will flash on the display.
Settings & options (factory default in bold)
TH6320U/TH6220D
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
0
Manual changeover (Heat/Cool/Off)
1
Auto changeover (Heat/Cool/Auto/Off)
2
Auto changeover only (Auto)
1
On**See page 8
1
Off
0
Fahrenheit
1
Celsius
5
Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
0
5/2 (programmable weekdays and weekends)
1
5/1/1 (weekdays, Saturday & Sunday programmable)
0
Comfort
1
Economy
90
Max. heat temperature setting is 90 °F (32 °C)
[Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)]
50
Min. cool temperature setting is 50 °F (10 °C)
[Other options: 51 °F to 99 °F (10.5 °C to 37 °C)]
6
or as otherwise noted.