10. Appendix

10.1. Help with problems

Problem
Cause
Teach-in failed
Batteries
inserted
incorrectly
Radio
connection
failure
HC60NG does
HC60NG
not react to set
and
point changes
HCW 80 not
on HCW 80
teached-in
After teach-in
Teach-in
red LED is on
procedure
and green LED
incorrect/
is flashing once
incomplete
every 3 sec
Position of
HCW 80
incorrect
Red LED of the
Communi-
HC60NG is on
cation loss
RF signal
blocked
Batteries of
HCW 80
exhausted
HC60NG
and
HCW 80 not
teached-in

10.2. Specifications HCW 80

Batteries
1.5 V, type LR06, AA
Frequency
868.3 MHz (transmitter)
Operating temperature
0 °C to 50 °C
Storage temperature
–20 °C to 70 °C
Humidity
5 % to 90 % relative humidity
IP class
30

10.3. Specifications HC60NG

Electrical
Receiver power supply
230 V AC (+10 %, –15 %), 50 Hz
Switch type
SPDT potential free
Output rating
24–230 V AC, max. 6.5 A resistive,
3 A inductive, cos φ = 0.6
Wire access
From the rear (wall box mounting),
(receiver only)
right an bottom
Remedy
Insert the batteries
correctly.
Eliminate interference
sources (metal, wireless
devices).
Correct installation site.
Repeat the teach-in.
Reset HC60NG.
Follow the teach-in
procedure as described
in section 5.
Repeat the teach-in.
Repeat the teach-in
keeping approx. 1 m
distance between
HCW 80 and HC60NG.
Relocate the HCW 80
(see section 0).
Replace batteries in
HCW 80
(see section 9).
Follow the teach-in
procedure as described
in section 5.
RF
RF operation band
SRD (868.0–868.6) MHz,
1 % duty cycle
RF communication
Typical 30 m in a residential
range
building environment
RF communication
Short, high rate transmissions to
technology
minimise air time and avoid
collisions
Blocking immunity
Receiver class 2 (ETSI EN300
220-1 version 1.3.1)
RF binding
Factory pre-bound with the room
unit HCW 80 (kit Y6630D1007
only)
Environmental & Standard
Operating temperature
0 to 40°C, max. 6.5 A
Shipping & storage
–20 to 55 °C
temperature
Humidity
Humidity range 0 to 90 % rh,
non-condensing
IP class
30

10.4. Approvals

Conforms to the requirements of the following directives:
HCW 80:
RoHS: 2011/65/EC
EMC:
R&TTE: 1999/5/EC
HC60NG:
RoHS: 2011/65/EC
EMC:
LVD:
R&TTE: 1999/5/EC
10.5. Device and function definition in
accordance with EN 60730-1
• Purpose of the device is temperature controlling
• Device fulfills protection class 2
• Independently installable electronic control system with
fixed installation
• Type of action is type 1.8
• Temperature of ball thrust hardness test for housing
components 75 °C and for live parts such as, for
example, terminals 125 °C
• EMC emitted interference test at 230 V∼, 50 HZ
maximum
• Pollution degree is 2
• Rated voltage is 4000 V (corresponding to overvoltage
category III)
• Software class is A

10.6. WEEE directive 2012/19/EC

Waste Electrical and Electronic Equipment
directive
• At the end of the product life dispose of the packaging
and product in a corresponding recycling centre.
• Do not dispose of the unit with the usual domestic refuse.
• Do not burn the product.
• Remove the batteries.
• Dispose of the batteries according to the local statutory
requirements and not with the used domestic refuse.
Appendix
2004/108/EC
2004/108/EC
2006/95/EC
11

Publicité

Table des Matières
loading