Troubleshooting Chart - Campbell Hausfeld FP2098 Serie Instructions D'utilisation Et Manual De Pieces

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions and Parts List

Troubleshooting Chart

Symptom
Possible Cause(s)
Compressor will not
1. Switch in OFF position
run
2. No electrical power at wall outlet
3. Compressor has reached automatic
shut-off pressure
4. Motor overheated
5. Loose electrical connection
6. ON / OFF switch bad
7. Pressure switch bad
8. Defective motor
Thermal overload
1. Lack of proper ventilation/room
protector cuts out
temperature too high
repeatedly
2. Excessive air usage, compressor too
small
Tank pressure drops
1. Open tank drain valve
when compressor
2. Loose connections (fittings, tubing,
shuts off
air hose, any connections, etc.)
3. Tank leaks
Compressor runs
1. Excessive air usage, compressor too
continuously / air
small
output lower than
2. Open tank drain valve
normal
3. Loose connections (fittings, tubing,
air hose, any connections, etc.)
4. Pump wore out
Excessive moisture in
1. Excessive water in tank
discharge air
2. High humidity
Safety valve pops
1. Defective pressure switch
open
2. Defective safety valve
www.chpower.com
Corrective Action
1. Make sure compressor is plugged in and switch is ON
2. Check circuit breaker or fuse at electrical panel.
3. Release air from tank until compressor restarts
automatically
4. Allow compressor to cool for approximately 30
minutes so thermal overload switch will reset. Make
sure compressor is run in a clean, well-ventilated area
where temperature will not exceed 100°F.
5. Check all electrical connections
6. Replace ON / OFF switch
7. Replace pressure switch
8. Replace pump / motor assembly
1. Move compressor to a clean,well ventilated area
where temperature will not exceed 100°F.
2. Decrease usage or purchase unit with higher air
delivery (SCFM)
1. Close tank drain valve
2. Check all connections with soap and water solution.
If a leak is detected, tighten. Or remove fitting and
apply pipe tape to threads and reassemble.
Do not disassemble check valve with
air pressure in tank; bleed tank.
3. Check entire tank for leaks with soap and water
solution
1. Decrease usage or purchase unit with higher air
delivery (SCFM)
2. Close tank drain valve
3. Check all connections with soap and water solution.
If a leak is detected, tighten. Or remove fitting and
apply pipe tape to threads and reassemble.
4. Replace pump / motor assembly
1. Drain tank, tilt tank to remove moisture
2. Move to area of less humidity; use air line filter
1. Replace pressure switch
2. Replace safety valve with genuine replacement part
6
FP2098 Series

Publicité

Table des Matières
loading

Table des Matières