ELECTRICAL CONNECTIONS

Do not connect more than one motor to a single
control unit.
Carefully respect the required connections.
A wrong connection can cause serious damage to
the control unit.
Line power supply
blue (common)
ground
brown (phase)
Motor power supply
blue (common)
black (phase)
ground
brown (phase)
AUTOMATIC functioning mode
Is the default mode; pressing
/
either opens or closes.
HOLD-TO-RUN functioning mode
Every time a button is pressed
element moves by 1/10 of a turn (that is, about 36 degrees).
Keeping the button pressed for more than two seconds
makes the motor move temporarily in automatic mode
until the fi rst stop, to then return to the hold-to-run mode.
START UP
All memorisation sequences have a time limit.
By powering up the operator: the control unit emits
an acoustic signal and makes the motor perform
a movement if no transmitters are memorised,
otherwise it just emits the sound signal.
Memorising the tx
Proceed within 1' after powering up the motor.
Any other blank motors or accessories coming within
the range of the TX must not be powered up.
Adjusting the limit switches on the shutters
To set the LS points, use the adjusting wand or a 4
mm hexagonal-head screwdriver.
- Unhook the shutters from the winder tube.
- Move the tube, which is empty of the winding part, until
the motor stops by itself.
- While keeping the button pressed, turn towards (+) the
LS adjusting screw until the proper position for attaching
the strip-tab.
- Attach the shutters to the tube.
- Give a "shutters UP" command until the motor stops.
I
F IT EXCEEDS THE REQUIRED UPPER POINT
move the shutters to a point just below the required one, and
invert the adjustment on the LS by turning the adjustment
, the moving element
screw towards (-).
I
F IT STOPS AT A POINT BELOW
adjusting screw towards (+) until the shutters reach
/
the moving
the required point.
Adjusting the LS on awnings
Adjust the LS with a safety margin, considering the
stretching of the fabric over time due to exposure to
the elements.
After a few days of operations, check the installation
and possibly adjust the LS again.
Automatic mode / hold-to-run mode
Cancelling all of the TXs in memory
This procedure cancels all of the TXs and the direction
of rotation stored in the memory.
Memorising an additional (2nd) TX
Up to 20 TXs can be memorised (including the weather
control units and / or any timers).
, interrupt the movement,
the required point, turn the LS
After cancelling, wait 10" before undertaking any
other operations.
MANAGING THE TX
An attempt to add a twenty-fi rst will cause the control
unit to emit fi ve consecutive beeps to signal that the
memory is full.
Stament CE of compliance -
Came Cancelli Automatici
S.p.A. declares that this device is compliant with the essential
requirements and other pertinent measures established
by directives 2006/95/EC, 2014/30/UE, 1999/5/EC.
Reference code to request an original copy: DDC RA H008.
Dismantling and disposal -
Before proceeding it is always
a good idea to check your local legislation on the matter. The
components of the packaging (i.e. cardboard, plastic, etc.)
are solid household waste and may be disposed of without
diffi culty, by simply throwing them out in the corresponding
recycle bins. Other components (i.e. control boards, radio
transmitter batteries, etc.) may contain hazardous substances.
These must therefore be handed over to specially authorised
disposal fi rms.
DISPOSE OF CAREFULLY!
The data and information in this manual may be changed at any time
and without prior notice.
119T70531 - ver. 2 2 - 02/2013