PVALX3/5 Power Vent Adaptor Kit Installation Instructions
These instructions are to be used in conjunction with those for the GPV and your appliance.
You will need:
Included in PVALX3:
W010-1777
W500-0551
W175-0309
W750-0445
Included in PVALX5:
W010-1777
W500-0551
W410-0029
W410-0017
W175-0001
W175-0013
W175-0309
W750-0444
Your appliance uses 5" and 8" flexible venting. When installing the GPV, the 4"/7"
reducer (W175-0309) is required. The reducer must be properly secured and sealed
to unit using high temperature sealant W573-0007 Mill Pac (not supplied) before
continuing with vent installation.
Terminal Installation
Refer to GPV installation instructions
note:
If installing a PVALX5, the 4" stainless liner must be used directly off the appliance.
VENT LENGTHS
When installing the venting, these parameters supersede the Vent Installation
Section in the appliance's Installation and Operating Instructions, use the
following guidelines:
Maximum horizontal vent run with no rise is 80 feet total.
H = HORIZONTAL RUN
MAX H+V
80 FEET
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
INSTALLER: Leave these instructions with the appliance.
This information supercedes that your appliance installation manual.
CONSUMER: Retain these instructions for future reference.
Assembly, firestop spacer
Plate, dilution
Connector, reducer 5/8" to 4/7"
Wire, Linear Power Vent (3')
Assembly, firestop spacer
Plate, dilution
Liner, 5' stainless steel
Flex Liner, 7"
Coupler, 4"
Coupler, 7"
Connector, reducer 5/8" to 4/7"
Wire, Linear Power Vent (5')
V = VERTICAL RUN
MIN H+V
10 FEET
MAX ELBOWS
SIX 90°
• 1(866)820-8686
4" x 7" Reducer (must
be sealed)
W415-2248 / A / 09.08.17
• www.napoleon replaces.com

Publicité

loading

Sommaire des Matières pour Wolf Steel PVALX3

  • Page 1 H = HORIZONTAL RUN V = VERTICAL RUN MAX H+V MIN H+V MAX ELBOWS 80 FEET 10 FEET SIX 90° W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 2 Under certain situations (longer vents), it may be necessary to add a dilution plate to the bottom portion of the gas power vent. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 3 2. Using a flat head screwdriver carefully release the 4 tabs (2 per side) to remove the top cover from the control board. note: It may be easier to remove the control board from the appliance. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 4 There is a 15 second pre-purge before the burner will light and a 120 second post-purge once the appli- ance is turned off before the blower stops. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 5: Longueurs Des Conduits D'évacuation

    H = COURSE HORIZONTALE V = COURSE VERTICALE MAX H+V MIN H+V COUDES MAX 80 PIEDS 10 PIEDS SIX 90° W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 6 Dans certain situations (évacuation plus long), il pourrait être nécessaire d’ajouter une plaque de dilution à la portion du bas du terminaison mécanique de gaz. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 7 2. Avec l’aide d’un tournevis à tête plâte, soigneusement relâcher les 4 pattes (2 par côté) pour enlever le couvercle du panneau de contrôle. note: Il peut être plus facile d’enlever le panneau de contrôle. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...
  • Page 8 Il y a une deuxième purge de 15 secondes préalable avant que le brûleur s’allume et une purge après 120 seconds quand l’appareil est éteint avant l’arrêt de la soufflerie. W415-2248 / A / 09.08.17 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon replaces.com...

Ce manuel est également adapté pour:

Pvalx5Pvalx3/5