Troubleshooting (cont.)
Symptoms
Cause
2. Running fill
A. Water level is
valve.
B. Flush valve
C. Flush valve is
3. Leaks from
A. Gaskets not
behind the bowl.
4. Carriage and
A. Insufficient
bowl flex when
used.
5. No water flow.
A. Supply stop
Kohler Co.
All manuals and user guides at all-guides.com
Recommended Action
A. Lower the water level
too high.
in the tank by turning
the knob at the top of
the threaded rod
counterclockwise until
the fill valve shuts off
when the water level
reaches the marked
waterline in the tank.
B. Replace gasket or
gasket or flush
flush valve as
valve are
necessary.
damaged.
C. Check flush valve and
sticking open.
actuating mechanisms
for free movement.
Push button actuators
should raise levers
then spring back
without force. Replace
components as
necessary.
A. Remove the bowl and
positioned
inspect all the gaskets.
correctly.
Reposition the gaskets
if needed. Lubricate
the gaskets so they
slide over the mating
part they seal.
Reinstall the bowl,
making sure the
gaskets stay in the
correct positions.
A. Add additional
support for
support members, and
frame.
mount the frame with
1/4" or larger lag
screws.
A. Open the supply stop
located in tank
(located on the left
is closed.
side).
19