Olsberg Orayonne Notice D'utilisation page 24

Chauffage à vitre radiante
Masquer les pouces Voir aussi pour Orayonne:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

If you intend to install the heater in a recess (i.e. glass panel flush with wall) with a gap between the wall
and the rear of appliance of 2 to 10cm, replace the M6x35 screws for the securing tabs of the wall
bracket with the included M6x65 screws and the d10x30 spacers (see Fig.7). Otherwise, the short end
of the hex screwdriver cannot reach the hexagon socket head! When changing the screws, ensure that
the spiral spring is properly installed between the securing tab and the wall bracket and that the lock nut
base is flush with the M6X65 screw.
For installation in all positions, we recommend using a hex screwdriver with a ball head that can be
operated at an angle.
Seal the four threaded bores in the wall bracket that are not used for screws with the four dummy plugs
(see Fig.7).
Fig.7: Wall bracket for vertical installation in recess
Caution: For safe installation ensure that the securing tabs are fitted at the correct positions for vertical,
horizontal or ceiling installation and that the appropriate predrilled holes are used for the screws!
Installation sequence:
• Use the properly dimensioned screw holes that are required for the chosen installation option
(vertical, horizontal, on ceiling). For details, see chapter "Distances for attachment of wall bracket").
• Align the wall bracket in the desired position on the wall, using the template and a spirit level. Mark
the positions of the holes to be drilled.
Caution: Observe minimum distances! Always use prescribed mounting bores!
• Drill holes with a diameter of 8mm for the supplied wall plugs (depth approx. 50mm).
Caution: The supplied screws and plugs are suitable for fixture to walls made in concrete, solid brick or
a similar solid material of dense structure. They are not suitable for cavity walls and walls made in
lightweight concrete. If you wish to mount the appliance onto ceilings or walls for which the supplied
fixtures are not appropriate, you must purchase suitable fixtures. The maximum permissible screw head
height is 10mm.
• Pre-mount the wall bracket with the supplied 6x60 screws and D=6.4 washers, align it using a spirit
level and screw it tight against the wall.
24
Hexagon head screw
M6x65 with cap
Spacer d10x30
Spiral spring
Lock nut
Dummy plug

Publicité

Table des Matières
loading