Arexx BS-1400GPRS Mode D'emploi page 23

Masquer les pouces Voir aussi pour BS-1400GPRS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. MANUAL BS-1400GPRS
E
N
G
L
1. Display mode button
2. Scroll button
I
3. Power-on indicator
4. Display
5. On - off switch
S
By pressing the display-mode button (1) different display modes can
H
be selected:
A- List of incoming measurements
B- Recent generated alarms
C- Graphical display of recent measurements
D- Result codes from executed rules
E- General settings
F- GSM status
G- SD card status
The scroll button (2) is used to scroll through the data.
Mode A displays the recent measurement data per line:
- rssi indicator: this indicates the received signal strength of the RF data signal
- sensor id: identification number of the sensor.
- time (hh:mm:ss)
- measurement value
- measurement unit, depending on the actual sensor.
Mode B displays the alarm report.
On the first line, the sensor id and time of the alarm are given, together with
the measurement value and unit.
The following lines are used to display the accompanying text of the rule.
Mode C displays the recent measurements in graphical form per sensor.
A graph for each sensor, will be presented it is accessible by the scroll button.
The graph shows the upper and lower boundary, the sensor id and unit. Also a
simple timescale is shown. The range of the graph is set in the general setting
section.