For designation of the BUS terminal, see the technical documentation for the heat
source.
3.3
Commissioning
Initial commissioning or commissioning after a reset
▶ Switch on the system / reset CR 10H.
Three dashes are displayed while the connection is being
established.
▶ Select and confirm H.C = HC1...HC4.
3.4
Settings in the service menu
Adjustment
Adjustment range
HC
HC1 | ... | HC4
E.1
– 3.0 ... 0.0 ... 3.0
S.1
nF.12.01
F.1
1 | 0
1) Values in bold = default setting
2) Only one CR 10H for each heating/cooling circuit (without zoning)
3) Turn the selector to read out the version in full.
A reset restores the default setting. In the event of a power failure, the settings
including the heating/cooling circuit allocation are retained.
6720830577 (2015/06)
Information for heating contractor | 5
1)
description
Heating/cooling circuits 1 to 4
Correction value for the room temperature
displayed
Software version
1: Reset
2)
3)
°C
°C
°F
°F