INSTALLATION
TRANSITION HEIGHTS:
TRANSITION HEIGHTS:
Dual Blower (WM2L = 600 CFM): no transition - 8" round duct will connect directly to the top
EN
of the liner.
Single and Dual Blower (WM1L + WM2L = 900 CFM): 6" round duct will connect directly to
Two Dual Blowers (Two WM2Ls = 1200 CFM):
CONNECTION DIAGRAMS
CONNECTION DIAGRAMS
Wall
12
©2020 Hestan Commercial Corporation
(CONT.)
the top of the liner; 8" round duct will connect directly to the top of the liner.
If using the optional multi-blower transition (AKVT6810, sold separately), a 10"
round duct connects to it 17-1/2" above top of hood..
See "VENT ACCESSORIES" on page 16.
Two 8" round ducts connect directly to the top of the liner.
If using the optional multi-blower transition (AKVT8812, sold separately), a 12"
round duct connects to it 16-1/2" above top of hood.
See "VENT ACCESSORIES" on page 16.
Connection diagram (30-36" width)
Wall side
1-3/4"
[4.4 cm]
Electrical
Motor cooling
vent
8" [20.3 cm] round
WM2L Dual blower (600 CFM )
5-1/2"
7-5/16"
[14 cm]
[18.6 cm]
side
Electrical (2)
WM2L Dual + WM1L Single blower (900 CFM)
5-1/2"
[14 cm]
[13.3 cm]
Connection diagram (42" width)
7-5/16"
[18.6 cm]
Motor
5-1/4"
cooling
[13.3 cm]
vent (3)
Centerline
of liner
8" Round
5-1/4"
Centerline
of liner
(Top view)
1-7/8"
[4.8 cm]
1-3/4"
[4.4 cm]
6" [15.2 cm]
round
(Top view)