Unit connectors
Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using
shielded cables is recommended.
Power connector - Mini DC connector. 7-20V DC, max 5W. See product label for
connection.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is
used from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system
or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A
stereo connector must be used for the audio out.
I/O terminal connector - Used in applications for e.g.
motion detection, event triggering, time lapse
recording and alarm notifications. It provides the
interface to:
• 1 transistor output - For connecting exter-
nal devices such as relays and LEDs. Con-
nected devices can be activated by AXIS
VAPIX AP, output buttons on the Live
View page or by an Event Type. The out-
put will show as active (shown under
Event Configuration > Port Status) if the
alarm device is activated.
• 1 digital input - An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass break
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under Event Configuration > Port Status).
• Auxiliary power and GND
Function
Pin number
GND
1
5V DC Power
2
Digital Input
3
Transistor
4
Output
All manuals and user guides at all-guides.com
Notes
Can be used as an alternative power supply
(7-20VDC) or to power auxiliary equipment
+5VDC (100mA).
Connect to GND to activate, or leave float-
ing (or unconnected) to deactivate.
Uses an open-collector NPN transistor with
the emitter connected to the GND pin. If
used with an external relay, a diode must be
connected in parallel with the load, for pro-
tection against voltage transients.
AXIS 211M Installation Guide
Pin 4
Pin 2
Pin 3
Terminal connector. Note that the pins
are numbered 1-4, right to left.
Specifications
Max load = 100mA
Must not be exposed to
voltages greater than
20VDC
Max load =100mA
Max voltage = 24VDC
(to the transistor)
±
Pin 1