Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
Natural Gas to Propane Includes
Kit W175-0636
1
Regulator
1
#56 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
(C)BL42
Kit W175-0740
1
Regulator
1
#55 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
(C)BL46
Kit W175-0635
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
(C)BL56
Kit W175-0738
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the
proper installation of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion shut off gas supply and disconnect electrical power.
1. Lift safety barrier up and out of appliance.
2. Open the glass viewing door and remove the media.
3. Remove the screws securing the log support to the base.
(FIG. 1)
4. Remove burner then log support (screw quantity varies by
model).
5. Using a deep socket, remove the main burner orifice. Use
a 7/8" wrench to ensure that the manifold tubing does not
twist or kink. Replace with the orifice supplied.
6. To convert the pilot, remove the clip from the side of the
pilot with pliers. Pull the pilot hood off. Using a 5/32" hex
head Allen key, remove the pilot orifice. Replace the pilot
orifice with the one supplied. Align the pilot hood back to
its original position and place the clip back on the pilot.
(FIG.2)
7. Before replacing the burner assembly, adjust the air
shutter. (See "VENTURI ADJUSTMENT" chart)
8. Reinstall log support.
9. Replace and re-secure the burner assembly ensuring that
the venturi fits over the burner orifice.
10. To convert the main valve, follow the instructions that are
supplied with the regulator assembly kit. IMPORTANT:
Use the screws provided with regulator.
11. The conversion data label must be filled out and attached
adjacent to the valve.
12. Turn on the gas supply and check for gas leaks by brushing soap
and water solution. Do not use open flame.
13. Replace the media. Then light the pilot and main burner to ensure that the gas lines have been purged.
14. Re-secure the door. Turn on the electrical supply to the appliance.
15. Reinstall safety barrier.
Purge all gas lines with the glass door open.
Assure that a continuous flow is at the burner before closing the door.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KIT FOR MODELS
(C)BL36-1 / (C)BL(P)42 / (C)BL(P)46 / (C)BL(P)56
These kits are for use at altitudes of 0 to 4500 feet.
(C)BL36-1
(C)BLP42
Kit W175-0817
1
Regulator
1
#55 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
(C)BLP46
Kit W175-0819
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
(C)BLP56
Kit W175-0821
1
Regulator
1
#53 Burner Orifice
1
#35 Pilot Orifice (P)
1
Conversion Data Label
Propane to Natural Gas Includes
Kit W175-0637
1
Regulator
1
#48 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL42
Kit W175-0741
1
Regulator
1
#45 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL46
Kit W175-0634
1
Regulator
1
#43 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BL56
Kit W175-0739
1
Regulator
1
#41 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
FIG.1
LOG SUPPORT SCREWS
FIG.2
1(866)820-8686
(C)BL36-1
(C)BLP42
Kit W175-0818
1
Regulator
1
#45 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BLP46
Kit W175-0820
1
Regulator
1
#43 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
(C)BLP56
Kit W175-0822
1
Regulator
1
#41 Burner Orifice
1
#62 Pilot Orifice (NG)
1
Conversion Data Label
HOOD
PILOT
ORIFICE
CAPUCHON DE
LA VEILLEUSE
INJECTEUR DE
W415-1722 / D / 04.19.22
VEILLEUSE
www.napoleon.com

Publicité

loading

Sommaire des Matières pour Napoleon BL36-1

  • Page 1 Purge all gas lines with the glass door open. Assure that a continuous flow is at the burner before closing the door. INJECTEUR DE W415-1722 / D / 04.19.22 VEILLEUSE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 2 (9,5mm - 12,7mm) Low flame (valley) LA SONDE Tall flame (peak) DE FLAMME W415-1722 / D / 04.19.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE...
  • Page 3 Purgez toutes les conduites de gaz avec la porte vitrée ouverte. Assurez-vous que l’arrivée de gaz au brûleur est continue avant de fermer la porte. W415-1722 / D / 04.19.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...
  • Page 4 LA FLAMME DOIT ENVELOPPER LA PARTIE SUPÉRIEURE DE LA SONDE DE FLAMME DE 3/8” (9,5mm) À 1/2” (12,7mm) Low flame (valley) Tall flame (peak) W415-1722 / D / 04.19.22 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada 1(866)820-8686 www.napoleon.com...

Ce manuel est également adapté pour:

Cbl36-1Bl42Cblp42Bl46Cblp46Bl56 ... Afficher tout