RayTek MI3 Serie Manuel D'utilisation page 98

Table des Matières

Publicité

Profibus
Byte
6
7...9
10 (0x0A)
11 (0x0B)
12 ... 22(0x0C ...16)
23 (0x17)
24 (0x18)
25 (0x19)
26 (0x1A)
27 (0x1B)
28 (0x1C)
29 (0x1D)
30 (0x1E)
98
Description
size of the diagnosis
reserved
highest address of the connected heads →up to which index the user data is valid
box error code
last MI3-command which created an error as answer; ASCII code
head_1 error code
head_2 error code
head_3 error code
head_4 error code
head_5 error code
head_6 error code
head_7 error code
head_8 error code
Table 14: Données de diagnostic
Bit Description
0
Self-test error
1
Box ambient temperature out of range
2
Sensing head communication error
3
Parameter error
4
Register write error
Table 15: Bits d'erreurs du diagnostic du boîtier
Bit
Description
0
Object temperature out of range
1
Ambient (internal) temperature out of range
2
Parameter error
3
Register write error
4
Self-test error
5
reserved
6
Head registered but not connected → cable break?
Table 16: Bits d'erreurs du diagnostic de la tête
Figure 86: Données de diagnostic sans erreur