Télécharger Imprimer la page

Daintree GE Current Tetra miniMAX GEMM2471-W1 Guide D'installation page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Tetra
miniMAX
®
Troubleshooting
Symptom
All letters are OFF
Some LEDs
appear dim
Some of the letters are
not illuminated
Shadows
Tips
• For optimal light uniformity in halo-lit applications the Tetra
and the light output from the Tetra
backlighting of the sign and will provide simple mounting for the Tetra
• A best practice for the supply wire at the point at which it is brought into the sign is to have a drip loop on the inside of the
letter to keep water from collecting on the Tetra
• These products are not required to be enclosed or protected from weather.
Maximum Loading per Tetra 24V DC Power Supply
SKU
Rating
GEMM2471-W1
GEMM2465-W1
24V DC,
GEMM2457-W1
14.7mA/module
GEMM2450-W1
0.35W/module
GEMM2441-W1
GEMM2432-W1
NOTE: The maximum loading claimed in the table is at ambient temperature 25°C (77°F).
For linear long runs, center connection to the LED strip is recommended to minimize voltage drop.
Maximum Remote Mounting Distance from Driver Output
25W Power Supply
80W Power Supply
100W Power Supply
180W Power Supply
300W Power Supply
Solution
• Check AC input connection and/or check circuit breaker.
• Check wire connection(s) at the Tetra
short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power supply
and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
• Ensure the overall length of the Tetra
• Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
• Ensure the overall length of the Tetra® LED System does not exceed the maximum load.
• Check wire connection(s) at the Tetra
short circuits. Properly terminate or replace the wire connection(s).
• Check that connections are the red striped wire (+) of the LED strip to the red wire (+) of the power
supply and the white wire (-) of the LED strip to the black or blue wire (-) of the power supply.
• Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire
connector orientation so that it does not cover any LEDs.
• Adjust LED layout to ensure uniformity of illumination on the face of the letter.
LED system should be directed back into the sign enclosure. This will allow for uniform
®
LED strip.
®
25W
80W
Power Supply
Power Supply
Note: Load shall
Note: Load shall
not exceed 1.04A
not exceed 3.3A
58 modules/
184 modules/
29 ft. (9.14 m)
92 ft. (28.95 m)
18 AWG/0.82 mm
16 AWG/1.31 mm
2
Supply Wire
120 ft./36.6 m
20 ft./6.1 m
20 ft./6.1 m
20 ft./6.1 m
20 ft./6.1 m
LED System and power supply for improper termination(s) or
®
LED System does not exceed the maximum load.
®
LED System and power supply for improper termination(s) or
®
LED modules should be mounted on UL recognized plastic
®
LED system.
®
180W Power Supply
100W
Note: Load shall
Power Supply
not exceed 3.8A
Note: Load shall
per each (of 2)
not exceed 4.0A
output channels
210 modules/
105 ft. (33.5 m)
220 modules/
per output channel
110 ft. (35.05 m)
420 modules/
210 ft. (67.05 m)
per power supply
14 AWG/2.08 mm
2
Supply Wire
Supply Wire
-
25 ft./7.6 m
35 ft./10.6 m
25 ft./7.6 m
35 ft./10.6 m
25 ft./7.6 m
35 ft./10.6 m
25 ft./7.6 m
35 ft./10.6 m
5
Installation Guide
300W Power Supply
Note: Load shall
not exceed 4A
per each (of 3)
output channels
220 modules/
110 ft. (35.05 m)
per output channel
660 modules/
330 ft. (105.15 m)
per power supply
12 AWG/3.31 mm
2
Supply Wire
-
-
40 ft./12.1 m
40 ft./12.1 m
40 ft./12.1 m
40 ft./12.1 m
2

Publicité

loading