Balluff BES M12MG1-YIC60B-S04G Notice D'utilisation page 51

Capteurs inductifs
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BES M12M_1-YIC_0_-S04G
Inductive sensors
8
IO-Link interface: Parameters, commands and events (continued)
8.4
Diagnostics parameters
Index
Name
Subindex
(dec)
(dec)
0x0024
Device
0x00 (0)
(36)
Status
0x0025
Detailed
0x00 (0)
(37)
Device
Status
0x0028
Process-
0x00 (0)
(40)
data In
0x0029
Process-
0x00 (0)
(41)
data Out
Operating temperature
0x0052
Device
0x01 (1)
(82)
Tempera-
ture
0x02 (2)
0x03 (3)
0x04 (4)
0x05 (5)
Operating hours counter
0x0057
Operating
0x01 (1)
(87)
Hours
0x02 (2)
0x03 (3)
Boot cycles counter
0x0058
Boot
0x01 (1)
(88)
Cycles
www.balluff.com
Name
Data format
(length)
UINT8
ArrayT of
OctetStringT3
ArrayT of
OctetStringT3
ArrayT of
OctetStringT3
Device Tempe-
INT16
rature Actual
Device Tempe-
rature Min
Device Tempe-
rature Max
Device Tempe-
rature Min
Lifetime
Device Tempe-
rature Max
Lifetime
Operating
UINT32
Hours Lifetime
Operating
Hours Mainte-
nance
Operating
Hours Power
Up
Boot Cycles
UINT32
(Lifetime)
Access
Value range
R
0x00 (0) = Device OK
0x01 (1) = Maintenance-
Required
0x02 (2) = Out-of-Speci-
fication
0x03 (3) = Functional-
Check
0x04 (4) = Failure
R
R
R
R
Actual device tempera-
ture
R
Minimum device tempe-
rature since power up
R
Maximum device tempe-
rature since power up
R
Minimum device tempe-
rature during lifetime
R
Maximum device tempe-
rature during lifetime
R
Operating hours since
lifetime.
Operating hours since
maintenance.
Operating hours since
power up.
R
Boot cycles since life-
time.
english
Description
Not used
Implemented
as dynamic list.
See Events
with Mode
appears/
disappears.
See sec-
tion 6.6.1 on
page 15
See sec-
tion 6.6.2 on
page 16
Values in °C
Can be reset
using Mainte-
nance Reset
system com-
mand
21

Publicité

Table des Matières
loading

Table des Matières