under sleep mode and the fan will turn to low speed automatically. The set temperature will increase by 1 ℃ after one hour, and increase
2℃ after two hours. After six hours the unit will stop running.
Child Lock operation:
1.
Press the button and hold "I" in cool mode "K" for 3 seconds to enter the child lock state. On screen will be shown "LC" after
active this function.
2.
Again press the button and hold "I" in cool mode "K" for 3 seconds to exist the child lock state. On screen will be shown present
room temperature after deactivate child lock function.
Swing "O" mode operation:
When the device is on, press button "O" , the vertical louver will on or off. When it is on, the louver can swing the left and the right sides.
Press the button "O" again, the louver will stop swinging.
Notice:
The main control board has memory function, when the device is ready to run but in stop status, the main control board can memorize the
initialization of working mode. When you turn on the unit, it will work as the same enactment of working-mode as last time, no need to reset
the working mode again.

REMOTE CONTROLLER

1. Slide the back cover to open and take off the isolating film on the batteries.
2. Put the batteries inside the slot, must be corresponding to the signs of "+" and "-" on the remote control.
3. For long time no use, take out the batteries.
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
To operate the device, aim the remote controller (4) at the signal receptor (3). The remote controller will operate the device at distance 5
meters when pointing at signal receptor of the device.

PROTECTIVE DEVICES

The protective device may trip and stop the appliance in the cases listed below:
1. at cooling mode: indoor air temperature is over 43°C (109°F)
2. at cooling mode: room temperature is below 15°C (59°F)
3. at dehumidifying mode: room temperature is below 15°C (59°F).
If the device runs in cooling "K" or dry "L" mode with door or window opened for a long time when relative humidity is above 80%, dew may
drip down from the outlet.
The protective device will work in the following cases:
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF - must be set again.
REMARK: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycling between the condenser
and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining
water. Please cut off the power supply, move the appliance to a suitable place, remove the drain plug, drain water completely. After the