Les langues disponibles

• High/low control: Auto 1, 2 or 3K
• Time switch with week program (7 switch blocks)
• Overtime timer: 0-180 min. per zone
• Signaling of burner malfunction
• Reset option to release a burner malfunction per zone
• PIN security to modify for example switching times and temperatures
• Languages: English, French, German and Dutch
• Calibration temperature sensor: range from -3°C to +3°C per 0,5°C
• Power: 230Vac / 50Hz.
• Modbus TCP/IP
• Embedded webserver
2.2 Technical details for external globe sensor
• Type name
• Article code
• Resistance
• Dimensions (wxhxd)
• Weight
• Electrical connection
• Degree of protection
2.3 External globe sensor resistance table
°C
- 50
- 40
- 30
- 20
- 10
0
+ 10
2.4 Factory settings Zone Control Infra
• Menu code
• Switching times
• Room temperature
• Calibration
4
: RSTF PT1000
: 06 29 082
: PT1000
: 85 x 85 x 27mm (40 mm incl. height external globe sensor)
: 42 gram
: 0.14-1.5mm²
: IP30
°C
803
+ 20
843
+ 30
882
+ 40
922
+ 50
961
+ 60
1000
+ 70
1039
+ 80
:
:
:
:
PT1000
1078
1117
1155
1194
1232
1271
1309
1000
Block 1 MA, DI, WO, DO, VR 08:00-17:00 hrs
Block 2-7 off
Day-time temperature 18°C
Night-time temperature 08°C
+0.0
°C
+ 90
1347
+ 100
1385
+ 110
1423
+ 120
1461
+ 130
1498
+ 140
1536
+ 150
1573