4. Maintenance
During inspection and maintenance work, no compressed air may be left on the motor.
Inspection and maintenance work should be performed by trained personnel, for instance via your
Gebuwin dealer.
For daily use, we recommend cleaning the air motor every 6 months. The air filter and infeed fittings should be
cleaned more often depending on the use. If after a long period of stoppage, the air motor fails to function properly,
we recommend adding a few drops of oil to the air inlet and then to try once more.
5. Malfunctions
Malfunction
Air motor does not turn or turns
too slowly
6. Service
For service and/or service parts, we refer you to your Gebuwin dealer in your neighbourhood. You can find the
service parts on the internet site www.gebuwin.com. On this site, you can also order any service parts.
Only use original service parts to avoid improper functioning of the device.
7. Environment
At the end of the life cycle, the various parts of the air motor should be removed in accordance with
the valid environmental requirements.
8. Warranty
Gebuwin BV provides a 1-year warranty on material and manufacturing errors on the GEBUWIN air motor
AM5000.
All manuals and user guides at all-guides.com
Cause
-
use of wrong connection
materials (see table 1)
-
pressure too low
-
insufficient lubrication
too high lifting load
-
rotor blades blocked
-
Correction
-
use correct mat with proper or
larger diameter
-
check pressure
-
check oil atomiser
check max. permissible lifting
-
load
check lubrication (service
-
manual)
10