Olsberg 14/71-3 Serie Notice D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Removing the control unit for servicing
The control unit can be easily removed in one
piece for servicing work.
This is done as follows:
Remove front panel of heater.
-
Remove right side panel if necessary.
-
Open the plastic adjustment element cover
-
(fig.30).
Pull off the adjustment knobs (fig.30).
-
Remove the front retaining screws left and right
-
(fig.30 and fig.31).
Pull the control unit forward and out (fig.32 and
-
fig.33).
Refitting takes place in reverse manner.
Make sure that:
the fluid regulator capillary tube is not bent or
-
damaged.
the connecting cables are not damaged.
-
the bimetal-strip is not bent or deformed.
-
the control unit slots onto the flaps in the rear
-
panel, made for this purpose.