Delivery and packaging
To facilitate transport and handling, the heater
cabinet (with built-in heating elements) and the
bricks (SP36) are packaged separately.
The packaging has be limited to the minimum nec-
essary for safe transport and is made entirely of
recyclable materials.
fig.1
Electrical connection
The combi heater is connected to two separate
single-phase circuit.
Storage circuit:
Voltage: 1/N/PE~230V
Charge period: 7h
Convector circuit:
Voltage: 1/N/PE~230V
According to safety instructions, each electrical cir-
cuit must be protected by a circuit breaker with an
all-pole contact opening of 3mm minimum.
Technical Data
Model
Voltage storage circuit
Nominal charge............................ kW
Storage capacity ........................ kWh
Heating elements
Core brick packs SP36
Voltage convector circuit
Direct heating element................. kW
Weight .............................. approx. kg
Dimensions
Width x Depth x Height
All manuals and user guides at all-guides.com
14/712-3
1 x 1,7kW
565 x 200 x 700
1)
............ mm
Heater positioning, minimum clearances
The heater is to be positioned with the feet pre-
mounted against a load-bearing wall and secured
according to this instruction and using the fixing
materials provided.
It is preferable to place the heater under a window
so that the cold air in this vicinity can be warmed,
causing natural convection.
The floor and/or the wall must be able to take the
weight of the heater. Please, therefore, note care-
fully the weights given in the Technical Data sec-
tion of this instruction. If in doubt, consult a building
engineer or architect.
The minimum clearances in fig.2 are to be ad-
hered to when positioning this heater.
To facilitate installation we recommend keep-
ing a distance of 150mm min. to the sides of
the heater.
A
B
L
fig.2
14/713-3
1/N/PE~230V
1,7
2,55
11,9
17,85
1 x 0,85kW
1 x 1,70kW
4
6
1/N/PE~230V
0,92
1,38
90
131
785 x 200 x 700
1)
Height includes feet. Height of feet: 70mm
14/712-3
14/713-3
14/714-3
345
505
725
110
140
140
565
785
1005
14/714-3
3,4
23,8
2 x 1,7kW
8
1,84
172
1005 x 200 x 700