Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The PCB board is the main component of the imago siren and allows its correct operation, the interface with
the alarm station, the control of the related device (i.e. the battery) are in conformity with the applicable
normative. Figure shows the PCB board and its relevant parts for which the installer has to set and program the
available function in accordance with the user needs.
JP1
JP2
JP3
F
TAMP
LI
BL
AL
UNIVERSAL VERSION
CLAMP
F
TAMP
LI
BL
AL
+ -
The inputs are controller with OC outputs normally open or closed (Start with negative/ negative missing), or
with a power relay that give or cut a 12V voltage (Start with negative/ positive missing). During the start up, an
auto-learning stage has to be set to establish the default values.
All manuals and user guides at all-guides.com

OPERATION

+
-
BUS VERSION
UNIVERSAL VERSION
TYPE
Output
Output
Input
Input
Input
Power Supply
quick installation guide
Universal version imago jumpers
JP1 = Tamper
Jumper inserted: Tamper ON
Jumper removed: Tamper OFF
JP2 = Alarm Time setting
Jumper inserted: Alarm time 3 min.
Jumper removed: Alarm time 10 min.
JP3 = Inputs configuration
Jumper inserted: polarity erasure.
Jumper removed: polarity recording.
CLAMP
A B
Power Supply
+ -
DESCRIPTION
Failure warning (faulty battery or internal electronic check)
Normally closed Link (NC)
to warn about the opening of the siren
Activation of the two auxiliary warning LEDs
(operable from an output OC or with a positive)
Activation of the only power LED (blinking)
(operable from an output OC or with a positive)
Activation of the acoustic and optical warning
(operable from an output OC or with a positive)
Power supply clamps 13.8V
imago
KS-BUS VERSION
TYPE
DESCRIPTION
Ksenia BUS
KS-BUS
terminals
Power supply
clamps 13,8V
11

Publicité

Table des Matières
loading

Table des Matières