1. IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of fire or electrical shock please assure that :
The appliance is disconnected from the mains before any form of
intervention.
The mains supply cabling and any extension cords are adequately sized,
according to the rated power of the pump and that there is no risk of the
electrical connections coming into contact with water.
Always use a Residual Current Device with IDn=30mA particularly in
installations pertaining to swimming pools, ponds or fountains.
Al the operation requiring the removal of the cover must be carried out by
qualified personnel
CAUTION: When the pump stops, the system will still be under pressure, therefore, before
any intervention, make sure to open a tap to relieve the system.
The device should only be used for clean water systems and is not suitable for use with
sea water, sewage, drainage systems, explosive, corrosive or any other hazardous liquids.
2. WARRANTY
The manufacturer guarantees this product for a period of 24 months from the date of
purchase; the unit must be returned together with this instruction manual, clearly indicating
the date of installation on the last page.
The warranty is automatically annulled if the appliance is subjected to any form of
unauthorized tampering, damage resulting from incorrect use and/or improper installation,
unsuitable environmental conditions or improper electrical installation.
The manufacturer declines any form of liability resulting from damages to buildings,
personal belongings and/or persons, caused by failure to install the necessary electrical
protection devices or inferior workmanshipIt is strongly recommended that the installation
and maintenance of this appliance be undertaken by qualified electricians, who are
expected to fully understand the contents of this instruction manual.
The manufacturer cannot be held responsible for any kind of damage to people and/or
things ensuing from the failure of any internal safety devices to intervene, with the
exception of compensation for the device itself if still under guarantee.

3.TECHNICAL DATA

Power Supply: ... ... ... ... ... ... ... ........115-230VAC ± 10% 50/60 Hz(Brio Green 230VAC)
Max current: ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ........ ...............12 A
Cut-in pressure range:....... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ..................... 1 ÷ 3.5 bar
Maximum allowed pressure: .........................................................................10 bar
Water temperature: .................................................................................5°÷55°C
Minimum ambient temperature: ........................................................................5°C
Maximum ambient temperature: .... ..................................................................45°C
Storage Temperature: ...................................................................................-10÷50°C
Hydraulic connections: .. .....................................................................1" GAS male
Protection degree: ............. ..........................................................................IP 65
Type ( Ref. EN 60730-1 ):...................................................................................1.C
Pressure gauge: .............................................................Ø 40mm 0:12 bar/0:170 psi
Pollution degree: ..................................................................................................III
Insulation category:.............................................................................................III
Ball Pressure Test: .............................................................................................85°C
Recommended torque for cable terminals: ..................................................2,5÷3,0Nm
Recommended torque for hydraulic connections: .......................................max.8,0Nm