IMPORTANT INSTRUCTIONS -
Models: D4S, D4SG, D4SH, D4SGH
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727900 Rev. H 12-18
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) This unit must be grounded.
g) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
h) Read all instructions before installing or using exhaust fan.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing D4S

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: D4S, D4SG, D4SH, D4SGH Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 Humidity Sensing Models For proper operation the humidity sensing fan will require a 3 way switch (not included). Screw Run wiring between the fan and the switch location. Make sure you leave enough wiring in each box to make the connections. At the switch box connect the black wire from the house to the common terminal of the switch.
  • Page 4 Install the ceiling mounting flange to cover any gaps which exist between the housing 1b. To adjust the setting, while the sensor is still flashing from Step 1a, press the button the and the finished ceiling. Put sealant (not provided) on inside edge of the ceiling number of times that corresponds with the amount of time you desire, for instance 3 times mounting flange to ensure that the flange is sealed to the ceiling.
  • Page 5: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Connector plug from motor is not plugged in. 1b. Turn off power to unit.
  • Page 6 Grill Springs 5S1202046 Ceiling Flange 5S1202050 Mounting Channel 5S1202123 Blower Assembly 5S1250100 Fuse Harness Assembly 5S1250011 Specific to Model D4S Qty. Description Replacement Part # Grill 5S1202048 Wire Compartment Assembly 5S1250103 Specific to Model D4SG Qty. Description Replacement Part #...
  • Page 7: Ventilateur D'évacuation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modèles: D4S, D4SG, D4SH, D4SGH Ventilateur d’Évacuation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9: Couvercle Du Compartiment De Câblage

    Compartiment de Câblage Extérieur : Enlever la vis du couvercle du compartiment à REMARQUE : Les fils du réceptacle du ventilateur pourraient nécessiter d’être tirés à câblage et mettre ce couvercle dans un endroit fiable (Figure 5). l’extérieur du compartiment pour le raccordement. Tirer uniquement les quatre fils lâches à l’extérieur du compartiment.
  • Page 10: Programmation Du Capteur D'occupation

    Installez la bride de montage au plafond pour couvrir tous les espaces qui existent entre 1b. Pour ajuster le réglage, tandis que le capteur continue de clignoter à partir de l’étape 1a, le boîtier et le plafond fini. Placez un scellant (non fourni) sur le bord intérieur de la bride appuyez sur le bouton le nombre de fois qui correspond à...
  • Page 11: Guide De Dépannage

    Fusible Suivez les étapes de la SECTION 5 Câblage pour accéder au porte-fusible situé à l’intérieur du compartiment de câblage. Pour remplacer le fusible, pressez le haut et le bas du porte- fusible ensemble tout en tournant le plus gros morceau dans une direction opposée aux languettes (Figure 14).
  • Page 12: Diagramme Des Pièces De Remplacement

    Bride du plafond 5S1202050 Canal de montage 5S1202123 Assemblée de la Soufflante 5S1250100 Assemblage du harnais de fusible 5S1250011 Particularités de modèle D4S # de pièce de Qté. Description remplacement Grille 5S1202048 Assemblée du compartiment du fil 5S1250103 Particularités de modèle D4SG # de pièce de...