2. Installation

The unit is adaptable for various process fittings (adapters to be
ordered separately as accessories).
• In the case of horizontal pipes mount the unit from the side, if pos-
sible (fig. 1). Do not mount it directly from the top or bottom.
• In the case of vertical pipes mount the unit in a place where the
medium flows upwards (fig. 2).
1
In the case of high temperature
gradients we recommend: align
the flow monitor in the longitu-
dinal pipe axis (unit connector in
the direction of the flow).
To avoid malfunction a minimum
distance between the flow moni-
tor and bends, valves or such like
must be observed.
• Min. 5 x pipe diameter
upstream,
• min. 3 x pipe diameter down-
stream.
22
2
3
4
min. 3 x D
min. 5 x D
D