Maintenance Instructions; Accessories; Lubrication - Desoutter SC2 Serie Mode D'emploi

Masquer les pouces Voir aussi pour SC2 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
English
When the torque is reached, the internal control
is disengaged and the air supply to the motor is
shut off. You should then shut off the air supply to
the tool, to allow it to reset.

ACCESSORIES

All accessories are available in the following
catalogues:
● Industrial tools
- UK
2050484013
- FR
2050484023
- GER
2050484033
- SP
2050484043
- IT
2050484053
- US
2050484063
- PORT
2050499023
- RUS
2050499013
- CHIN
2050499033
- KOR
2050519203
- MEX
2050519213

LUBRICATION

This tool is fitted with blades which can
operate without lubricated air. However,
a small amount of oil allows the tool to
provide full power and lengthens its life.
The use of dry air with no trace of oil
may reduce the life of blades.
This is a DRYLINE tool designed to
operate on a totally dry air line i.e.
one without any oil or water moisture.
DRYLINE tools can also operate on a
lubricated or partly lubricated air line thus
allowing easy interchangeability with
existing installations.
If lubrication is required an air line
lubricator should be fitted down stream
of the filter.
Use ISO VG 15 (27652).
Note: This tool is fitted with blades
which can operate without lubricated air.
However, a small amount of oil allows the
tool to provide full power and lengthens
its life.The use of dry air with no trace of
oil may reduce the life of blades.
09/2017

MAINTENANCE INSTRUCTIONS

C
19 / 64
The use of spare parts/accessories
other than those originally supplied
by the manufacturer may result in a
drop in performance and/or increased
maintenance / noise level / vibrations,
and as the result, the full cancellation of
the manufacturer's liability.
● Service should be carried out at
intervals of 1000 hours use.
● All torque figures ± 10%.
● When ordering spare parts, always
specify the tool's model number and
serial number and the catalogue
number of each spare part.
When disposing of components,
lubricants, etc... ensure that the relevant
safety procedures are carried out.
Never connect a part assembled tool to
the air supply. The rotor blades in this
tool have a PTFE content. The normal
health and safety recommendations
concerning PTFE must be observed
when handling these rotor blades.
● Do not smoke.
● Motor components must be washed
with cleaning fluid and not blown clear
with an air line.
● Wash hands before commencing any
other activity.
● The muffler must be replaced when
soiled. Do not clean it or re-use it.
6159932490_08
Series: D

Publicité

Table des Matières
loading

Table des Matières