The Fountainhead Group 183435 Manuel D'utilisation Et D'entretien page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLE
Sprayer will not turn on (no
audible hum of the pump.)
Sprayer turns on (audible hum of
pump heard) but will not spray.
Sprayer turns on but only sprays
at low pressure.
Pump will not fully prime.
TROUBLESHOOTING
LOOK FOR
1. Battery inserted correctly. See
Inserting the Battery.
2. Battery charged. Check Battery
condition. See Battery Charge
Indicator.
3. Power Switch in the ON (I)
position.
4. Battery damaged, over heated,
or non-functional? Visually
inspect the Battery for damage.
Use the Charger to diagnose any
Battery problem. See Charging
the Battery.
5. Hose is already pressurized so
the pump has turned off auto-
matically.
1. No liquid in Tank.
2. Shut-off clogged.
3. Nozzle clogged.
4. Pump not yet primed.
1. Shut-off clogged.
2. Nozzle clogged.
3. Pump not yet primed.
1. Low liquid level in Tank.
2. Pump was run dry without
liquid prior to refilling Tank.
3. Chemical residue build-up in
Tank (likely also in Pump) due to
improper or inadequate cleaning.
4. In-Tank Filter improperly
installed, missing, or damaged,
allowing debris to enter Pump.
REMEDY
1. Insert Battery correctly.
2. Charge Battery as needed. See
Charging the Battery.
3. Set the Power Switch to the ON
(I) position. See Powering-On and
Spraying.
4. Replace Battery if damaged or
non-functional. Allow Battery to
cool if overheated.
5. Open the Shut-off (depress
Lever) to see if the Sprayer starts
spraying and the Pump turns on.
1. Add liquid to Tank. See Filling
the Sprayer.
2. Clean Shut-off. See Shut-off
Maintenance.
3. Clean Nozzle. See Nozzle
Maintenance.
4. Allow time for pump to prime
(up to 30 seconds).
1. Clean Shut-off. See Shut-off
Maintenance
2. Clean Nozzle. See Nozzle
Maintenance.
3. Allow time for Pump to prime
(up to 30 seconds).
1. Add liquid to Tank. See Filling
the Sprayer.
2. Set Power Switch to OFF (O)
position. Open Shut-off (depress
Lever) until all pressure is
relieved. Set Power Switch to On
(I) position.
3. Clean sprayer. See Cleaning &
Storage. If necessary, repeat with
warm water and mild detergent
mixture, allowing mixture to stay
in pump for up to 1 hour prior
to rinsing. Replace Pump Unit if
necessary.
4. Clean sprayer. See Cleaning &
Storage. If necessary, repeat with
warm water and mild detergent
mixture, allowing mixture to stay
in pump for up to 1 hour prior
to rinsing. Replace Pump Unit if
necessary.
page 12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

190670

Table des Matières