Teaching in the manual transmitter
Actuate the teach-in key (E 12) on the receiver for approx. 1 second. Then actuate top left transmitting key for at least
3 seconds. A maximum of 10 transmitters can be taught in according to this order.
Deleting the transmitter
When the teach-in key (E 12) on the receiver is actuated for at least 5 seconds, the transmitter is reset to its delivery
status. Following this, the manual transmitter can be taught in.
Functions at the manual transmitter
Pump 1 off (0), Pump 1 on (I). Pump 2 off (0), Pump 2 on (I). Invoke memories 0 and I. Reassign memories 0 and I
(factory setting: 0 = 25 % and 1 = 75 %). Activated pumps (+) = larger water quantity, (-) = smaller water quantity.
Battery change
Push the lid beneath the keys down and insert new batteries, type 23A. Ensure correct polarity.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
− Prior to reaching into the water, disconnect the power supply to all units used in the water.
− Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
− Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
− In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
Cleaning the pump
Remove pump from the bottom strainer casing:
Figure (F)
− Remove hoses from the unit. Open the clips (6) and remove the strainer top casing.
− Undo both union nuts (8) and remove the Y distributor (9).
− Release the clamps (4) and take pumps out of the bottom strainer casing.
Note for the assembly: For secure pump fastening, ensure that the clamps (4) engage.
Open the pump housing:
Figure (G)
− Remove screws and the pump housing.
− Clean the pump housing, impeller and flat seal under clean water using a brush.
− Check parts for damage and replace, if necessary.
Reassemble in the reverse order.