Battery discharge and charge specifications
Parameter
Output voltage
Constant output current
Emergency power
Battery discharge current
Output current must be less than 1.5 A! If larger, ask our technical support.
L
N
GND
Do not test the emergency function until the battery has been charged for at least 16 hours.
A test button + corresponding indicator are included in the scope of delivery for testing the
battery kit.
Connect the indicator and test button according to the instructions. Fix the LED in the
ceiling. Countersink the test button into a hole in the ceiling (Ø 7 mm) and, if necessary, fix
it with a nut or glue it in place. Pressing the button briefly starts a function test for 5 sec.
Charge the battery at least 5% (30 min). Every 7 days, the emergency lighting unit, the
battery and the LED module are tested with the self-test. Initial test: The test is carried out
automatically 24 hours after the initial installation. Half-year test: The test is carried out
every 180 - 182 days and lasts 5 days.
Function indicator LED
green
flashes green quickly
flashes green slowly
lights red
Flashes red quickly
flashes slowly red
flashes green and red
Max.
10 - 90 V DC
34 - 380 mA
4,6 - 5,2 W
700 - 820 mA
N
L
battery kit
GND
L
driver
N
8
Luminaire -
Luminaire +
driver -
driver +
LED /
Test button
Indicator
Battery
Output -
Output +
functional, charging process
Self test running
Endurance test runs
Luminaire fault
Battery capacity error
Battery error
Battery operation