Hazards encountered by the combination of water and electricity
• The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly
connected or misused.
• Prior to reaching into the water, always switch off the mains voltage to all units used in the water.
Correct electrical installation
• Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
• A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regula-
tions.
• The device may only be connected if the electrical data of the device and the power supply coincide. The device data
is to be found on the device type plate, on the packaging or in this manual.
• For your own safety, please consult a qualified electrician.
• Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
• Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
• Protect the plug connections from moisture.
Safe operation
• Operation of the unit is only permitted with the protection hood fitted. This protects connections and plugs from rain
and splash water.
• The unit, the connections and plugs are not water-proof and must not be routed or installed in water.
• Never operate the unit if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cable.
• Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
• Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
• Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modifications to the unit.
Installation
So
How to install the unit:
• Remove the protection hood from the unit.
• Set-up the unit horizontally and water-protected, at a dry location, at least 2 m from the edge of the pond (B, C).
• Fully insert the ground stake (3) into the soil.
• Place the unit onto the ground stake (insert the ground stake in a corresponding mounting).
• Check its stability.

Electrical installation

This is how to connect the power supply:
• Push the female connector of the power supply (6) onto the unit plug (7).
The connection is made on the unit rear (D).
Commissioning/start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Only operate the unit with the protection hood fitted.
• Ensure that the unit is installed in a flood protected position at a distance of at least 2 m from the water.
Teach-in manual transmitter
Check the function of the manual transmitter by actuating one of its buttons. The LED of the manual transmitter must
light up. A maximum of 10 transmitters can be taught in. Depending on the terrain, the range is up to 80 m. When the