Interval boiling
In order to avoid continuous boiling rotate the temperature controller backward until
the control light goes off. The device will be set to interval boiling mode.
When the water temperature in the tank drops the control light will come on and the
device will heat the water. The thermostat adjusts the energy consumption to the
needs and saves it.
Adding water
CAUTION! Burn hazard!
During filling of hot tank the released hot steam may cause burns of hands,
arms, and face! Do not remove the lid during boiling
Rotate the temperature controller counterclockwise to position
Before refilling with water leave the device for a few minutes for coling down.
NOTE!
The thermostat will turn the device off when there is no (or too little) water in the
tank. When the protection against dry operation is activated, disconnect the
device from the socket and wait for cooling down before refilling.
Operation of drain tap
Pulse mode
Press the drain tap lever down.
The tap will open. To close the
tap release the lever.
Continuous mode
Pull the tap lever completely backwards.
It will be locked in such position.
The tap will open. To close the tap
pull the lever forwards.