6.4 Repeater 2 levels function
The repeater function of the 2 channels receiver is used to increase the range between
transmitters and receivers. When the radio signal from a transmitter is received, it is
retransmitted to the associated receiver via a maximum of two repeaters. Radio signals are
received and transmitted automatically.
a) On the receiver, activate the slave RTL mode by a short press (approximately 0,5s) on
LRN and CLR simultaneously. This mode is confirmed by the regular flashing (orange)
of the 2 LEDs; then short press (approximately 0,5s) CLR. This mode is confirmed by the
red LED 1 flashing.
b) The current configuration is displayed by the number of LED 1 flashing:
1 - repeater off
2 - activated repeater, level 1
c) To change the mode of operation of the repeater, short press CLR the number of times
corresponding to the desired mode (b). Each press is acknowledged by maintaining LED
1 on for the time of the press. The new configuration is stored and enabled, after 1,5s
without any press. As soon as the flashing restarts, the new configuration is displayed
and editable again (back to b).
d) To exit this function, short press (approximately 0.5s) on the LRN button. The output is
confirmed by stopping the flashing of LED 1. In the absence of activity, this function stops
automatically after 30 seconds.
Note:
- This function is disabled on delivery of the receiver.
6.5 Current safety function
When an overcurrent is detected on one or more receiver outputs, a flashing red LED fault
informs the user of the concerned output(s). The receiver then deactivates the accused outputs
and the red LED(s) flashes until the user has cleared the fault.
To clear the fault, press (approximately 0.5s) the CLR button. No reprogramming is necessary
for restarting. Checking the electrical connection and the connected loads is essential.
Note:
- The value of the detection threshold is not configurable (factory value).
7. Troubleshooting
7.1 New or existing installation
• Check the circuit breaker, the electrical supply and the load connected to the receiver
associated with this sensor (qualified electricians).
• Check the connected load and the connecting cables (qualified electricians).
• If the receiver functions at a shorter distance relative to the sensor, it is subject to
interference or used outside the transmission range.
• Search the system environment for changes that could cause the interference (for example
movement of metallic cabinets, furniture or partitions).
• Use the sensor or receiver in a more suitable location.
• Clear the receiver and perform a new learn process.
7.2 Automatic activation of the receiver
• The cause may be the activation of a sensor external to the system which has by chance
been programmed on the receiver.
• Clear the receiver and perform a new learn process.
7.3 Limitation of the range of the radio signals
• Transmitter/receiver used close to metallic objects or close to materials containing metallic
elements. Observe a distance of at least 10 cm.
• Humidity in the materials.
• Device emitting high frequency signals such as: audio and video systems, computers,
electronic ballasts or fluorescent tubes. Observe a distance of at least 0.5 m.
7.4 Contacts
E-mail : ............................
contact@trio2sys.fr
8. Recycling of the device
In accordance with European Directive 2012/19 / EU on waste electrical and
electronic equipment and its implementation in accordance with national laws,
this logo means that devices must not be thrown away with household waste.
The hazardous substances they are likely to contain can harm health and the
environment. Have these devices taken back by your distributor or use the
selective collection means made available by your municipality.
9. Declaration of conformity
This product can be marketed and distributed in the countries of the European Union. Hereby
0
TRI
SYS declares that radio equipment 10020107 is in compliance with directive
2
2014/53/EU, known as the RED Directive.