Willtek 4100 Série Manuel De L'utilisateur page 182

Table des Matières

Publicité

Willtek
4100
Tester information = A03
+
La numérotation de
l'identificateur ne correspond
pas toujours à des nombres
qui se suivent. Les lacunes
sont intentionnelles.
Call from mobile = A10
Call from base station = A11
Release from mobile = A12
Release from base station = A13
MS power level = A15
Codage utilisé dans les procès-verbaux
Identifier
A02;
Extension Bit status* 0
Multiband info*
5
MS Pwr class 1*
4
MS Pwr class 2*
1
MS Pwr class 1900* 3
EFR Speech mode 1
*) Only if Classmark 3 is available
Identifier
A03;
Tester model
4106
Tester serial
120025
number
User name
MILLER
User company
Willtek
Firmware version
2.10
Identifier
A10;
Result
0
Identifier
A11;
Result
1
Identifier
A12;
Result
0
Identifier
A13;
Result
0
Identifier
A15;
Result
0
Level
5
A FAIL result stands for a failed MS power level change signalling sequence.
A PASS result means a setting or a correct signalling sequence.
0=No, 1=Yes
0=single band mobile
5=GSM900+1800
6=E-GSM900+1800
valid for (E-)GSM900
valid for GSM1800
valid for GSM1900
(Tri-band only)
0=Only FR available
1=EFR available
Model
Serial number
0=PASS, 1=FAIL
0=PASS 1=FAIL
0=PASS 1=FAIL
0=PASS 1=FAIL
0=PASS, 1=FAIL
Power level
6-29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41074107l4107s

Table des Matières