6
Technical specifications
Type
Temperature range
Operation
Storage
Relative humidity
Protection class as per EN 60529
Plug connector inserted or provided
with protective cap
Protection against electric shock
(protection against direct and indirect
contact as per IEC/DIN EN 60204−1)
Protection against explosion
(as per EU guideline 94/9/EG, EN
50021 and EN 50281−1−1), do not dis
connect when under tension
Elektromagnetic compatibility
Interference emitted
Immunity against interference
1)
The component is intended for industrial use.
20
CP−FB11−E
− 5 ... + 50 °C
− 20 ... + 70 °C
95 %, non−condensing
IP65
by means of PELV circuits
(Protective Extra−Low Volt
age)
II 3 G/D EEx nA II T5 X
− 5 °C Ta + 50 °C
T 80 °C IP65 (year of manu
facture see Ex−identification
on the product). Plugs or
adapters of the electric con
nections must comply at least
with protection class IP64!
Tested as per DIN EN
61000−6−4 (industry)
Tested as per DIN EN
61000−6−2 (industry)
Festo CP−FB11−E 0503f English