14.0 ALARMS
ALARM LIST
Faulty cell probe
Faulty core probe
Faulty humidity probe
Faulty evaporator probe
Faulty condenser probe
Faulty electronic valve probe
Faulty LP transducer
Faulty HP transducer
Cell high temperature protection
Cell high temperature
Core probe high temperature
Power board high temperature.
Door open
Communication with power board
interrupted
Water filter replacement
Clean the condenser
Faulty humidifier water load
Faulty heating humidifier
High pressure
HP switch intervention
Interrupted communication with
electronic valve
46
POSSIBLE CAUSE
Possible fault of the cell probe
Possible core probe fault.
Core probe not connected.
Anomaly or failure in the detection of humidity.
The alarm may appear if a program with humidity
is started after a blast chilling or freezing cycle.
Possible fault of the evaporator probe
Possible fault of the condenser probe (Levtronic)
Possible failure of the refrigerant gas
management electronic valve.
Possible failure of the low pressure transducer.
Possible failure of the high pressure transducer.
The cell temperature exceeds 100°C.
It activates if the setpoint is not reached after 4
hours of continuous compressor operation
The core probe temperature is too high.
The power board is operating beyond the
maximum temperature limits.
The door is open
The control board cannot communicate with the
power board.
The cartridge of the water filter upstream from
the humidifier has reached the end of its life
(Levtronic)
The condenser is dirty and does not guarantee
the correct cooling of the cooling system.
Faulty humidifier water load (Levtronic)
Faulty heating humidifier (Levtronic)
Excessive pressure detected by the high pressure
transducer.
Programs are interrupted due to the inability to
control the electronic valve.
SOLUTION
Contact the authorized technical service centre. The
machine will run with a temporary temperature
value calculated as the average of the needle probe
and the evaporator probe.
Check the probe plug is inserted correctly, in case
disconnect the probe and gently clean the contacts.
Do not force the connector during the insertion to
avoid damaging the contacts. If the problem
persists, contact the authorized technical service
centre.
With the alarm active, Levtronic will not use the
humidifier to manage humidity. Warm Levtronic up
with a manual cycle at 40° without humidity to dry
the probe. If the problem persists, contact the
authorized technical service centre.
Contact the authorized technical service centre. It is
possible to continue using Levtronic, defrosting and
fan management will not be optimized.
Contact the authorized technical service centre. It is
possible to continue using the appliance,
performance will not be optimal.
Contact the authorized technical service centre.
Contact the authorized technical service centre.
Contact the authorized technical service centre.
The compressor is activated in cooling mode, if the
temperature does not drop, disconnect Levtronic or
Modi Active from the power supply and contact the
authorized technical service centre.
Check that there has been no excessive load of hot
product, check that the condenser of the machine is
clean, check the ventilation in the technical
compartment is correct.
If the product it is in is too hot, remove it and let
the product cool for a few minutes.
Check the ventilation in the technical compartment
is correct. Stop the cycle and let the appliance cool
down.
Close the door, if the alarm persists, contact the
technical service centre.
Disconnect the appliance from the mains and
contact the authorized technical service centre.
Cartridge replacement. Do not use programs with
humidity or steam when the cartridge is empty: risk
of failure of the steam generation system.!
See par. 15 Cleaning the condenser
Contact the authorized technical service centre and
close the water stop-cock.
Contact the authorized technical service centre.
Check that the condenser is clean, the appliance
has enough space to evacuate the heat from the
condenser and/or that the product inserted is not
too hot. For water-cooled appliances, check the
correct water supply. If the problem persists,
contact the authorized technical service centre.
Disconnect the appliance from the power line for 10
seconds, if the problem persists, contact the
authorized technical service centre.