2. Maintenance
Besides the procedures described in
item 4.3 the satellite is maintenance-
free. However, we recommend
cleaning the satellite occasionally in
connection with the cleaning of other
equipment in the area. he satellite is
maintenance-free.
3. Start
3.1 New system
In order to ensure a problem-free
start up of a new system the pipe
system must be flushed and bled:
Bleeding the pipe system
1. Turn on the water supply to rinse
and bleed the entire system.
Open the tap furthest away until
no air or dirt comes out. Then
rinse and bleed the next tap and
continue until the tap closest to
you has been rinsed and bled.
2. Mount satellites.
3. Chemical supply lines are only to
be bled by authorised personnel
appointed by Ecolab.
4. Daily operation
4.1 Start
1. Check that water- and air sup-
plies for the system are open.
(see A, Fig.7, air). Activate cen-
tral chemical supply if present.
2. Set the function that you want.
Use the system referring to
"User Guide" instructions.
4.2 Stop
1. Press "0" on the control panel to
stop.
2. Close the water supply
3. Close the air supply(A, Fig. 7)
4. De-activate the chemical supply,
switch off closing valves if any.
Note: It is important to shut off the
water, air and chemistry, when the
machine is left after use because:
• If the air supply is open when
the satellite is not in use, air may
seep into the water pipe. If this is
the case the system may have to
be bled again.
• The water separator, which is a
part of the air regulator, is only to
be emptied when the air is shut
off.
6
Fig. 7
• If the water and the air supply is
closed, but the outlet tap on the
satellite is open, chemical can be
pumped out on the floor etc. This
is only possible in connection
with direct or pre diluted chemical
supply.
It may be necessary to bleed the
pipes and the satellite again after it
has been closed for a longer period
of time (holidays, and the like)
4.3 Rinsing the chemistry
supply
IMPORTANT: The chemistry sup-
ply must always be rinsed thor-
oughly after use.
The following does not concern
units (satellites) with central
chemical supply. Rinsing of central
supply lines are only to be carried
out by Ecolab, or people appoint-
ed by Ecolab.
Remains of detergent or disinfect-
ants can clog the injector so it needs
to be rinsed or replaced. The follow-
ing procedure will clean the injec-
tor for detergent and/or remains of
disinfectants.
1. Remove User Pack, if any.
2. Hold the rinsing bottle with
clean water tightly against the
suction opening (with User Pack)
or against the hose (without
User Pack). Alternatively, you
can place a User Pack with
clean water in the holder or –
without User Pack – place the
hose in a bucket of clean water.
3. Activate the hose handle until
clean water comes out of the
nozzle (approx. 30 seconds).
Note: This procedure should be
followed for both the detergent and
disinfectant side (if this is installed).
5. Service
Service may only be carried out by
authorized and qualified personnel.
Warning: The satellite must only be
serviced when there is no pressure
on the system.
1. Turn off the water and air supply
2. Turn of the power supply.
3. Disconnect the chemical supply.
4. Depressurise the system.
5.1 Components
5.1.1
Non-return valve/inlet side
(water, air, detergent)
Maintenance free
If defective: Call service technician
110001402
5.2 Recycling and scrap-
ping
Recycle the wrapping and scrap the
machine according to recommenda-
tions from the local authorities.