Omcan CE-CN-HP212M Mode D'emploi page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b. Pull-out the converter from the cover.
c. Position of converter when using Propane(L.P.)
d. Install the converter cover to the regulator.
Note: The arrow in the regulator indicates the flow direction of the gas.
6. Re-install the cast burners, trivets and tray.
7. Check leakage and re-install other parts.
8. Ignite the pilot burner and check flame state.
Turn the knobs to "High".
If the burner does not ignite, open the pilot valve more. If the pilot flame appears larger than necessary, turn it
down and reset burner ignition. The pilot flame should be as small as possible but large enough to guarantee
reliable ignition of the burners when the knobs are turned to "|"
Note: Please check leakage before re-install the control-panel.
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type, as shown on unit nameplate, agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National
Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in
9
Installation

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ce-cn-hp424mCe-cn-hp636m437334373443735

Table des Matières