Regency P36E-NG4 Guide D'installation Et D'utilisation page 20

Table des Matières

Publicité

INSTALLATION
Description
Attic Insulation Shield 12"
Attic Insulation Shield -
Cold Climates
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA only)
Chimney Conversion Kit Masonry
(USA only)
Wall Firestop
Colinear Flex Connectors
FPI
946-506/P
Vent Guard (Optional) for AstroCap
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
946-605
Starter Collar Increaser 4" x 6-5/8" to 5" x 8"
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Mettre les conduits d'évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu'à la sortie.
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
S'assurer qu'aucune section du système d'évacuation n'est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
un risque d'incendie.
20
Selkirk
Simpson
®
Direct Temp™
Direct Vent Pro
46DVA-IS
N/A
N/A@ FPI
36"
N/A
N/A
Disc.
4DT-HKA
46DVA-KHA
4DT-HKB
(Changed Components)
Disc.
4DT-VKC
46DVA-VCH
N/A
46DVA-HC
N/A
See 46DVA-HC
4DT-HHC
N/A
4DT-HVC
46DVA-08A
4DT-SC
N/A
4DT-ST14
N/A
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-VCH
N/A
46DVA-HC
N/A
46DVA-RD
N/A
46DVA-VCE
N/A
46DVA-KCA
N/A
46DVA-KCB
N/A
46DVA-KCC
N/A
46DVA-KMC
N/A
46DVA-WFS
N/A
46DVA-ADF
N/A
4" x 6-5/8" Venting
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
American Metal
Metal-Fab™
Products®
Sure Seal
Amerivent Direct
4DAIS12
N/A
4DAIS12
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DHC
4DHT
4DVC
4DVT
4DSC
4DSC
4D12S
4DST14
4D36S
4DST36
N/A
4DVS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-205
Vinyl Siding Shield for Riser Vent Terminal
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-206
Vinyl Siding Standoff for AstroCap
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
P36E-4 Foyer à évent direct à dégagement zéro
Security
ICC Excel
Secure- Vent®
Direct
SV4RSA
N/A
N/A
TM-4AS
SV-SHK
N/A
SV-HK
N/A
SV-FK
N/A
N/A
TM-4VT
N/A
TM-4DHT
SV4CHC-1
TM-4HT
SV4CGV-1
TM-4VT
SV4FC
TM-SC
SV4STC14
TF-4FA
SV4STC36
TF-4FB
SV4VS
TM-VSS
SV4VS
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4DS
N/A
N/A
N/A
TM-4CA6
N/A
TM-4CA7
N/A
TM-4CA8
N/A
N/A
N/A
TM-4TR
N/A
N/A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P36e-lp4P36-ng4 gaz naturelP36-lp4 propane

Table des Matières