OEG 650 001 127 Notice De Montage Et D'utilisation page 68

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

68
4.10
List of default settings
GB
No.
Description
0
Automatic restart
1
Programming Start/Stop times
2*
Adjustment of temperature difference for
restart
3**
Adjustment of compressor shutdown margin
4
Auto-activation time before de-icing
commences
5
De-icing activation temperature
De-icing deactivation temperature
6
Max. de-icing duration
7
8
Compressor thermal protection
9
Maximum temperature
10
Filtration pump servo-control mode
11
Pump stopping time when temperature is
reached (if setting 10 = 1)
12
Reserved – do not modify
13
Setting for selecting pump operating mode
14
Water intake temperature
15
Water outlet temperature
16
Coil temperature
17
Air outlet temperature
18
Ambient air temperature
* Setting 2 is for modifying the temperature deviation in relation to the required
temperature, causing the heat pump to restart.
Example: If the value of setting 2 is +3 °C, the heat pump will restart after the required
temperature (e.g. +27 °C) has been reached as soon as the pool temperature drops down
to +24 °C (27 – 3).
** Setting 3 is for modifying the exact temperature for heat pump shutdown.
Example: By configuring the compressor shutdown at +2 °C and the required tempera-
ture at +27 °C, the heat pump will stop working automatically as soon as the pool tem-
perature reaches +29 °C (27 + 2).
Adjustment range Default setting
0 = Off
1
1 = On
0 = once
1
1 = daily
adjustable from
+3 °C
+2 up to +10 °C
adjustable from
0 °C
0 up to +3°C
adjustable from
40 min.
30 to 90 min.
adjustable from
-7 °C
0 to -30°C
adjustable from
+20 °C
+2 up to +30 °C
adjustable from
8 min.
0 to 15 min.
adjustable from
+118 °C
+95 up to +120 °C
95-96-97-98-99-A0-
displayed values
A1-A2-A3-A4-A5-
b8
A6-A7-A8-A9-b0-b1-
b2-b3-b4-b5-b6-b7-
b8-b9-C0
+25 up to +40 °C +40 °C
0 = normal/
1
1= special
adjustable from
15 min.
3 to 20 min.
0 / 1
1
0 = only cooling
1
1= cooling +
heating
2 = only heating
-9 up to +99 °C
-9 up to +99 °C
-9 up to +99 °C
-9 up to +99 °C
-9 up to +99 °C
Swimming pool heat pump
Remark
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable
adjustable (see
section 5.2)
adjustable
adjustable
adjustable
actual data
actual data
actual data
actual data
actual data

Publicité

Table des Matières
loading

Produits Connexes pour OEG 650 001 127

Table des Matières