Manuel d'utilisation du niveleur de quai RHH50
SCHÉMAS ÉLECTRIQUES
100
DEPUIS ALIMENTATION ET DISPOSITIF DE PROTECTION DE SURETE DU CLIENT
110-120V, MONOPHASE, 60Hz, UTILISER FUSIBLES DOUBLES TEMPORISES 25.0A
101
L1
102
N
G
103
SECTIONNEUR A FUSIBLE
(DE TIERS)
104
VOIR NOTE 9
105
106
107
108
H2(RD)
109
FUSIBLE DOUBLE TEMPORISE
'ARRET D'URGENCE'
H2(RD)
110
111
H3(RD)
112
H3(RD)
113
114
H5(RD)
115
116
H3(RD)
117
118
119
VERS BOITIER DE COMMANDE
DOK-LOK POUR INTERCONNEXION
DE DISPOSITIF DE RETENUE
120
H3(RD)
121
LE BLOC DE CONTACT EST N.O. LORSQUE
L'ARRET D'URGENCE N'EST PAS NECESSAIRE
122
H3(RD)
16
VOIR NOTE 3
1FU1
1L1
1L1
DUMMY
N
N
N°12GA MIN.
90°C
VOIR NOTE 4
10FU1
1L1(BK)
0.5A 250V
'MONTEE'
H2A(RD)
H2B(RD)
PB3
CR1-1
H2A(RD)
(14)
(11)
H5
H5(RD)
H5B(RD)
'LEVRE SORTIE'
H4A(RD)
H4(RD)
PB1
H7
H7(RD)
PB2
H3
(BORNE SUSPENDUE DE MAINTENANCE)
1. CONFIER TOUTE L'INSTALLATION ET LA MAINTENANCE A DU PERSONNEL QUALIFIE.
2. CABLAGE EXTERIEUR D'ALIMENTATION D'ENTREE – VOIR TABLEAU DES TAILLES DE
CABLE MINIMUM.
3. ALIMENTATION DEPUIS SECTIONNEUR POUR COMMANDER LE BOITIER ET LE
MOTEUR DU NIVELEUR LE CABLAGE EXTERIEUR DOIT ETRE UN FIL EN CUIVRE
N°14GA MINIMUM, 60°/75°C SUFFISAMMENT ISOLE POUR LA TENSION D'ENTREE.
4.TOUT CABLAGE EXTERIEUR DE COMMANDE DOIT ETRE UNIQUEMENT UN FIL EN
CUIVRE N°14GA MINIMUM, 60°/75°C, SUFFISAMMENT ISOLE POUR LA TENSION D'ENTREE.
5. TOUT LE CABLAGE INTERIEUR DU BOITIER DE COMMANDE DOIT ETRE UN FIL EN
CUIVRE ROUGE N° 18GA MINIMUM, 90°C SAUF INDICATION CONTRAIRE, SUFFISAMMENT
ISOLE POUR LA TENSION D'ENTREE.
6. COUPLES DE SERRAGE:
CONTACTEUR 8.9-22 LB-IN (MINI.-MAXI)
RELAIS DE SURCHARGE: 16 LB-IN
BORNE DE TERRE: 36 LB-IN
BORNIER: 5.0-5.6 LB-IN (MINI.-MAXI)
FIGURE 14 - SCHÉMA ÉLECTRIQUE - 120V./60HZ. MONOPHASÉ
1MCR
1L1(BK)
N(WH)
CR1-2
H2B(RD)
(11)
(14)
BORNIER
CAVALIER
H5A
H5A(RD)
LS2
'VERROUILLAGE DE PORTE'
(4)
(3)
G
ILLUSTRE AVEC
N.O.
PORTE FERMEE
LS1
'INTERRUPTEUR DE FIN
DE COURSE ARTD'
H4
12(WHT)
4(BLK)
H12
G
N.O.
SOLENOIDE 1
LEVRE SORTIE
X2 (WHT)
7 (BLK)
X2/N
120Vca, 0,3 A
7. LS1 FOURNI PAR RITE-HITE AVEC NIVELEUR POUR ARTD.
LS2 FOURNI PAR RITE-HITE OU DES TIERS POUR PORTE BASCULANTE.
8. VOIR MANUEL D'UTILISATION POUR DES INSTRUCTIONS COMPLETES.
9. NOTES SUR LE SECTIONNEUR A FUSIBLE:
- LE SECTIONNEUR A FUSIBLE N'EST PAS FOURNI PAR RITE-HITE PRODUCTS
CORPORATION. IL DOIT ETRE FOURNI PAR DES TIERS ET INSTALLE SELON LA
DERNIERE EDITION DES REGLEMENTS UL508A ET NEC.
- UN SECTIONNEUR DE CIRCUIT DE DERIVATION DOIT ETRE INSTALLE DANS UN
RAYON DE 50 PIEDS ET ETRE VISIBLE DEPUIS L'EMPLACEMENT DU BOITIER DE
COMMANDE.
(REF. DERNIERE EDITION DE NEC, SECTION 430)
10.
LEGENDE:
INDIQUE RACCORDEMENTS DE CABLE A TRAVERS LE BORNIER
INDIQUE CABLES EXTERIEURS
INDIQUE RACCORDEMENT PAR CONNECTEUR DE FIL
INDIQUE RACCORDEMENT PAR PRISE MALE/FEMELLE
MOTEUR DE NIVELEUR, 1 HP
(VOIR TABLEAU INTENSITE MAXI. MOTEUR)
3450 TR/MIN, 115V, MONOPHASE, 50/60Hz
1OL
(PROTECTION THERMIQUE AVEC
T1
REINITIALISATION AUTOMATIQUE)
M
BLU
ORG
BRN
G
T2
T1
VOIR NOTE 3
N(WH)
RELAIS D'INTERFACE ESB
CR1-1
N(WH)
(A1)
(A2)
120VAC
CR1-2
N(WH)
(A1)
(A2)
120VAC
N(WH)
H5B(RD)
N(WH)
TMR1:
IMPULSION
3
2
1
L
~
~
V
(-)
(+)
S1
4
6
R
5
T
N(WH)
Pub. n° 1336 - Juillet 2012
RED
WHT
YEL
BLK
T2
CIRCUIT D'ARRET
D'URGENCE
COMMANDES
NIVELEUR
CIRCUIT
ARTD
CIRCUIT
SORTIE
LEVRE