Télécharger Imprimer la page

Calpeda VARIOMAT 2 Instructions Originales Pour L'utilisation page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
1. Introduction
We strongly suggest that the operator carefully
reads and follows the information contained in
this instruction manual for the frequency
converter.
Symbol used:
This symbol indicates high voltage
hazard. It draws attention to components
or procedures that could represent a
potential danger to the health and welfare
of the operator.
This symbol is used to draw the operator's
attention to situations of potential danger
for people or for operations that could
cause damage to the product.
2. Special warnings regarding
the frequency converter
We strongly suggest that the operator
carefully reads and follows the information
contained in this instruction manual for the
frequency converter.
The FREQUENCY CONVERTER should
NEVER be opened or tampered with
and guards that come with it should
never be removed.
The
frequency
installed, adjusted and maintained by
qualified personnel who understand the
risks involved.
The frequency converter must be fitted
with
voltage
protection devices, in accordance with the
prevailing safety standards.
The connection of the alarms can
distribute power even when the frequency
converter is turned off. Ensure that there
is no residual voltage on the terminals of
the alarms.
All the power terminals and other
terminals must be inaccessible after
installation is completed.
converter
must
surge
and
overload
The maximum output frequency must not
exceed the design frequency of the pump
being controlled. Operating at a frequency
higher than the allowable frequency can
cause higher current absorption and
damage to the device.
If it is necessary to remove the frequency
converter, remove only the covers
required in order to disconnect the
electrical cables. Take care not to damage
the electronic cards.
Failure
regulations not only causes risk to
personal safety and damage to the
equipment, but also invalidates every right
to assistance under warranty.
Electro-magnetic compatibility.
The frequency converter is constructed in
compliance with European standard 2014/30/EU.
Responsibility:
The manufacturer is not liable for malfunctioning if
the product has not correctly been installed,
damaged, modified, and/or run outside the
recommended work range or not in accordance
with other indications given in this manual.
The Manufacturer declines all responsibility for
possible errors in this instructions manual, if due to
misprint or error in copying.
The Manufacturer reserves the right to make any
be
modifications to products that it may consider
necessary or useful, without affecting the essential
characteristics.
The responsibility of the manufacturer is limited to
the product and excludes costs or greater damage
caused by incorrect installation.
3. Types
Type
(single-phase)
Variomat 2 11MM
Variomat 2 13MM
Type
(three-phase)
Variomat 2 11MT
13
to
comply
with
Freqeuency converter Standard power
max current output
A
11
13
Freqeuency converter Standard power
max current output
A
11
the
safety
V230 motor
kW
0,55 - 1,5
2,2
V230 motor
kW
0,55 - 2,2

Publicité