Télécharger Imprimer la page

filtreau UVC POOL BASIC 16W Mode D'emploi page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION OF THE DEVICE; SEE FIGURE 3
The device must be placed in a dry, well-ventilated area, out of direct sunlight. Never place the device directly
after the pH regulator and/or salt electrolysis. The best position is – if possible – after the filter. The installation
must always be carried out vertically. Take into account accessibility for maintenance (see also Maintenance and
disassembly).
1. Undo the lock nut (H) from the housing (D) and keep this for the connecting link (I) under 7.
2. Carefully unpack the UV-C lamp (J) and slide this into the quartz sleeve (K).
3. Put the UV-C lamp (J) into the lamp holder (L) and slide this further into the quartz sleeve (K).
Make sure that the O-rings (M1 & M2) sitting properly.
4. Tighten the nut (N) hand-tight in the housing (D).
5. Mount the pipe clamps (O) in the required place. The device will hang from these. (Please take into account the
length of the cables, see 6).
6. Mount the electronics box (R)) in the required place. (Please take into account the length of the cables).
7. With the lock nut (H), fasten the connecting link (I) to the housing (D), making sure that the O-rings (M1 & M2)
are seated properly.
8. Place the apparatus in the pipe clamps (O) and glue the connecting link (I) between the pipes.
9. Ensure that enough water flows through the device and plug the device into the appropriate socket.
You can see if the UV-C lamp is on by looking through the transparent connecting link (I).
Check the whole assembly for possible leaks.
10. The device can be turned off by simply pulling the plug out of the socket.
MAINTENANCE AND DISASSEMBLY
The device needs maintenance at least once per half year. During maintenance, the device must be disconnected
from the mains. Chalk deposits and possibly algae must be removed from the quartz sleeve (K) and the housing (D).
The UV-C lamp (J) only has to be changed after 9,000 hours of use. The actual lifetime is dependent on the number
of times it is turned on and off.
1. Unplug the device from the mains and close the pipes.
2. Ensure that the water is drained out of the device.
3. Loosen the bolt (N) and disconnect the UV-C lamp (J) from the lamp holder (L). If necessary, you can also replace
the lamp.
4. Carefully raise the quartz sleeve (K).
5. The quartz sleeve (K) can be cleaned with an appropriate cleaner. After cleaning, rinse the quartz sleeve (K)
thoroughly. Use a soft cloth to avoid scratches!
6. The housing (D) can now also be cleaned. This can be done with a brush; do not use any chemicals.
7. After cleaning, place the quartz sleeve (K) back in the housing (D). Ensure that the O-ring (M1 & M2) is seated
properly and that the quartz sleeve (K) slides into the holder.
8. Put the UV-C lamp (J) into the lamp fitting (L) and slide both into the quartz sleeve (K).
9. Tighten the nut (N) on the housing (D) hand-tight. (See 9 under Installation of the device).
N.B. To change the housing and/or the electronics box, the earth must be completely disconnected. The component
parts must be saved because they do not come with a new housing or electronics as standard.
If in any doubt seek the advice of a certified electrician!
GB
5

Publicité

loading

Produits Connexes pour filtreau UVC POOL BASIC 16W

Ce manuel est également adapté pour:

Uvc pool basic 40wUvc pool basic 80w